Aorfix AAA Stent Graft Body with Aorflex Delivery System SG-HBB-24-111-80-18-A12-22Recalls & reported problems
Lombard Medical Limited · Aorflex AAA Stent Graft Body with Aorflex Delivery System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055715606523), received between Jan 11, 2016 and Jan 11, 2016 — classified as 1 injury.
The most frequently reported specific device problem is “Malposition of Device” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Malposition of Device1
Patient problems
- Aneurysm1
- Obstruction/Occlusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 11, 2016Malposition of Device; Malposition of Device
THE ORIGINAL PROCEDURE WAS PERFORMED ON (B)(6) 2015. STENT GRAFTS WERE PLACED FROM THE RIGHT APPROACH FOR THE EVAR. IPSILATERAL RIM WAS FULLY EXPANDED. BUT CONTRALATERAL LEG DID NOT EXPAND ENOUGH BECAUSE THE DISTAL END OF THE LEG WAS PLACED DOWNWARD NARROW PORTION THAN PLANNING POSITION. THE PHYSICIAN PERFORMED THE TOUCH-UP FROM THE JUNCTION PART TO THE DISTAL END OF THE RIM BY RELIANT BALLOON CATHETER. FINAL ANGIOGRAPHY WAS REVEALED THE TYPE 4 ENDOLEAK. THE PATIENT WILL BE FOLLOWED-UP. ON (B)(6) 2015 (4 DAYS LATER FROM THE OPERATION) CT WAS REVEALED THE LEFT RIM OCCLUSION. THE PHYSICIAN PERFORMED THE F-F BYPASS FOR THE PATIENT BY USING A PROPATEN PROSTHESIS (8MM).
Patient problems: Aneurysm; Obstruction/Occlusion
MAUDE report 5356590 ↗
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page