Aorfix AAA Stent Graft Body with Aorflex Delivery System SG-HBB-24-126-63-20-A12-22Recalls & reported problems
Lombard Medical Limited · Aorflex AAA Stent Graft Body with Aorflex Delivery System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055715606653), received between Oct 29, 2015 and Oct 29, 2015 — classified as 1 death.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- No Apparent Adverse Event1
Patient problems
- Aneurysm1
- Death1
- Vascular Dissection1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathOct 29, 2015No Apparent Adverse Event
THE ORIGINAL PROCEDURE WAS PERFORMED ON THE (B)(6) 2015. THE INFORMATION RECEIVED ON THE SAME DAY DETAILS THE FOLLOWING: THE CASE WAS NOT SUCCESSFULLY COMPLETED. THE PATIENT DIED DURING THE PROCEDURE. THIS WAS NOT GRAFT RELATED.A SMALL INDUCED DISSECTION IN THE CONTRALATERAL EXPLORATORY CAUSED A CARDIAC EVENT AND PRESSURE DROP. DESPITE 70 MINUTES OF REANIMATION AND MOMENTARY PRESSURE INCREASE AND EMERGENCY MEASURES, THE PATIENT COULD NOT BE SAVED. FURTHER INFORMATION RECEIVED ON THE (B)(4) 2015 DETAILS THE FOLLOWING: THE MAIN BODY WAS IMPLANTED WITHOUT ISSUES. IT WAS NOT POSSIBLE TO CANNULATE THE CONTRA LATERAL SIDE. THE LEFT COMMON ILIAC ARTERY WAS VERY TORTUOUS AND IT WAS NOT POSSIBLE TO STRAIGHTEN WITH A STIFF WIRE. A 8F FLEXOR SHEET AND A WIRE WERE USED TO CROSS AN ANGULATED SECTION. THIS PARTICULAR STEP MAY HAVE CAUSED THE DISSECTION. A CONVERTER WAS IMPLANTED TO PREVENT THE LOSS OF BLOOD AND TO STOP THE BLEEDING.IMPLANTS USED IN THIS CASE:MODEL NUMBER LOT NUMBER EXPIRY DATE MANUFACTURE DATE UDI1) SG-HBB-24-126-63-20 1) CP58496-1 1) 06 JAN 2017 1) 06 JAN 2015 (B)(4)
Patient problems: Aneurysm; Death; Vascular Dissection
MAUDE report 5186958 ↗
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page