Aorfix AAA Stent Graft Body with Aorflex Delivery System SG-HBB-27-111-80-14-A12-22Recalls & reported problems
Lombard Medical Limited · Aorflex AAA Stent Graft Body with Aorflex Delivery System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055715608664), received between Apr 19, 2016 and Apr 19, 2016 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Aneurysm1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 19, 2016Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) THE PHYSICIAN INSERTED THE MAIN BODY BY THE RIGHT APPROACHING AND DEPLOYED THE CONTRA-LATERAL SOCKET. AFTER CANNULATING THE CONTRA-LATERAL LIMB, HE DEPLOYED THE IPSI-LATERAL LIMB OVERALL AND USED A RELIANT BALLOON CATHETER TO BETTER LAND THE DEVICE AT THE EXTERNAL ILIAC ARTERY. AFTER THE INSERTION OF THE CONTRA-LATERAL LIMB, IT WAS DEPLOYED AND MOULDED AROUND THE EXTERNAL ILIAC ARTERY. THEREAFTER, ALL THE DEVICES WERE MOULDED WITH USE OF A BALLOON CATHETER. THE ANGIOGRAPHY REVEALED A TYPE IA ENDOLEAK. THEREFORE, HE ADDED AN EXCLUDER CUFF TO RESOLVE IT AND THIS TIME, THE ANGIOGRAPHY REVEALED A TYPE IV ENDOLEAK. THE PROCEDURE WAS FINISHED. HE DECIDED TO FOLLOW-UP THE PATIENT. ON (B)(6) THE PHYSICIAN CONFIRMED AN ENDOLEAK AGAIN WITH USE OF CT. IN ORDER TO IDENTIFY DETAILS, HE PERFORMED AN ANGIOGRAPHY AND DETERMINED THAT IT WAS A TYPE IB ENDOLEAK AT THE RIGHT DISTAL PORTION. ADDITIONAL INFORMATION AS OF (B)(6) 2016 - RE-INTERVENTION THE ANGIOGRAPHY REVEALED A TYPE IB ENDOLEAK, BECAUSE THE SEALING ZONE OF THE FISHMOUTH TROUGH AT THE RIGHT DISTAL SIDE WAS ONLY 5 MM OR SO. THEREFORE, THE PHYSICIAN PLACED (B)(4) AS AN ADDITIONAL DEVICE TO THE RIGHT IPSI-LATERAL LIMB. THEREAFTER,
Patient problems: Aneurysm
MAUDE report 5586362 ↗
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page