Aorfix AAA Stent Graft Body with Aorflex Delivery System SG-HBB-31-96-80-14-A12-22Recalls & reported problems
Lombard Medical Limited · Aorfix AAA Stent Graft Body with Aorflex Delivery System · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05055715612081), received between Jun 1, 2016 and Jun 1, 2016 — classified as 1 death.
The most frequently reported specific device problem is “Difficult to Advance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Difficult to Advance1
- Patient-Device Incompatibility1
Patient problems
- Aneurysm1
- Death1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathJun 1, 2016Patient-Device Incompatibility; Difficult to Advance; Adverse Event Without Identified Device or Use Problem; Patient-Device Incompatibility; Difficult to Advance; Adverse Event Without Identified Device or Use Problem
ORIGINAL EVAR WAS PERFORMED (B)(6) 2016. REPORTED TO LOMBARD MEDICAL ON 27 APR 2016 (NO REPORT OF DEATH). FOLLOWING THE IFU, A MAIN BODY (HBB-31-96-80) WAS INSERTED FROM THE LEFT APPROACH AND A CONTRA-LATERAL LIMB (HBL-90-14) WAS PLACED. TYPE IA ENDOLEAK WAS CONFIRMED. ALTHOUGH IT WAS ATTEMPTED TO ADD A DISTAL EXTENDER (HDE-14-51) IN THE IPSI-LATERAL LIMB, IT WAS IMPOSSIBLE TO PUSH UP THE DEVICE DUE TO THE EXCESSIVELY TORTUOUS COMMON ILIAC ARTERY. IN ORDER TO ADDRESS THE SITUATION 2), THE PHYSICIAN ATTEMPTED TO ADD A PROXIMAL EXTENDER FROM THE CONTRA-LATERAL SIDE OVER THE EGOIST GUIDE WIRE ((B)(4)) BY INFLATING A BALLOON CATHETER AROUND THE PROXIMAL NECK. HOWEVER, THE DEVICE WOULD NOT ADVANCE AND IT WAS SWITCHED TO ADVANCE IT FROM THE IPSI-LATERAL SIDE. ALTHOUGH THOSE ATTEMPTS WERE MADE, THE DEVICE WOULD NOT ADVANCE IN THE END. FINALLY, THE PHYSICIAN PLACED A CUFF (GORE, 32 MM) INSTEAD. AS A RESULT, THE TYPE IA ENDOLEAK WAS RESOLVED. THE PHYSICIAN FINISHED THE PROCEDURE, EVEN THOUGH THE FINAL ANGIOGRAPHY REVEALED A TYPE IV ENDOLEAK. IN ORDER TO WATCH IT, THE PATIENT WILL BE FOLLOWED-UP FROM NOW ON. PATIENT PASSED AWAY ON (B)(6) 2016. THIS WAS REPORTED TO LOMBARD MEDICAL ON 10 MAY 2
Patient problems: Aneurysm; Death
MAUDE report 5690605 ↗
Other System, Endovascular Graft, Aortic Aneurysm Treatment devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page