pRESET® Delta Thrombectomy Device (6mm x 30mm) PRE2-6-30Recalls & reported problems

Phenox Limited · The pRESET Delta Thrombectomy Device is designed to restore blood flow in the neurovasculature by mechanical removal of thrombus in patients experiencing acute ischemic stroke due to large vessel occlusion with thrombus. The device is designed for use in large vessels of the neurovasculature such as the internal carotid artery (ICA) and middle cerebral artery (MCA). · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05391530910460), received between May 27, 2026 and May 27, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Material Separation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Separation1

Patient problems

  • Stroke/CVA1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 27, 2026Material Separation

    IT WAS REPORTED THAT THE 5X40 WAS DELIVERED TO A M1 CLOT AND UPON RETRIEVAL INTO A SOFIA 88 THE PRESET DETACHED UNINTENTIONALLY, A GOOSE NECK SNARE WAS USED TO TRY TO RECOVER THE STENT BUT DID NOT WORK, ANOTHER 6X30 WAS INTRODUCED TO TRY TO DEPLOY AND RETRIEVE THE 5X40, THAT 6X30 ALSO DETACHED UNINTENTIONALLY. THIS MDR REPORT IS FOR THE PRESET 6X30 DEVICE. AN ADDITIONAL REPORT WILL BE SUBMITTED FOR THE 5X40 DEVICE ADDITIONAL INFO WAS RECEIVED ON 18 MAY 2026: 1. HAS THE PRESET DELTA 6-30 BEEN DISCARDED BY THE HOSPITAL, OR IS IT AVAILABLE FOR RETURN AND ROOT CAUSE ANALYSIS? ONLY THE PUSHERS WERE AVAILABLE AS THEY SEPARATED FROM THE STENT, AND THE STENTS WERE LEFT BEHIND IN THE PATIENT. 2.FOLLOWING THE DETACHMENT OF BOTH PRESET DEVICES, WERE ANY FURTHER ACTIONS TAKEN TO REMOVE THE COMPONENTS FROM THE PATIENT'S ANATOMY? THE FIRST STEP RETRIEVER DETACHED. THAT'S WHEN THE SECOND ONE WAS USED TO TRY AND SNARE AND BRING THE FIRST DEVICE OUT. SUBSEQUENTLY, THE SECOND DEVICE DETACHED. SNATCH WERE USED TO TRY AND LASSO THE DEVICES. BUT NOTHING WAS UNSUCCESSFUL. 3.WHAT WAS THE FINAL OUTCOME OF THE PROCEDURE? AFTER BOTH THE DEVICES DETACH AND WE'RE NOT ABLE TO BE RETRIEVED OR REMOVED. THEY WERE

    Patient problems: Stroke/CVA

    MAUDE report 25298080 ↗