Supreme™ 401860Recalls & reported problems
St. Jude Medical Cardiovascular Division · Electrophysiology Catheter · Class 2
All models of Supreme (16)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05414734201513), received between Jul 13, 2018 and Oct 28, 2025 — classified as 2 injuries.
The most frequently reported specific device problem is “Difficult to Remove” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K894500); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Remove2
- Material Separation1
Patient problems
- Foreign Body In Patient1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryOct 28, 2025Difficult to Remove; Material Separation; Difficult to Remove; Material Separation
DURING AN ATRIOVENTRICULAR NODAL REENTRANT TACHYCARDIA PROCEDURE, THE CATHETER BECAME TANGLED AROUND ITSELF WHEN GOING UP THE ILIAC VEIN. IT WAS ATTEMPTED TO UNTANGLE IT BUT SUPPORT FROM AN INTERVENTIONAL SURGEON WAS REQUIRED. WHEN ATTEMPTING TO REMOVE THE CATHETER, IT BROKE AND THE KNOT THAT HAD FORMED WAS STUCK IN THE VEIN. A VASCULAR SURGEON WAS THEN CALLED TO REMOVE THE KNOT THAT REMAINED. THE KNOT WAS REMOVED WITH EASE AFTER THE INITIAL INCISION WAS CUT A LITTLE LARGER THAN BEFORE.
Patient problems: Foreign Body In Patient
MAUDE report 23405777 ↗InjuryJul 13, 2018Difficult to Remove; Difficult to Remove
RELATED MANUFACTURING REF: 3005334138-2018-00206. DURING THE PROCEDURE, THE MAPPING AND FIXED CURVE CATHETERS BECAME ENTANGLED AROUND AN INFERIOR VENA CAVA FILTER (IVC) FILTER FROM THE GROIN. THE IVC FILTER WAS SNARED WITH A DEVICE FROM A SUPERIOR IJ ACCESS SITE. ONCE THE IVC FILTER WAS SECURED WITH THE SNARE DEVICE, THE ENTANGLED CATHETERS WERE FREED FROM THE IVC FILTER. THE FILTER WAS THEN COMPLETELY EXTRACTED USING THE SNARE AND A SHEATH FROM THE SUPERIOR ACCESS. THE HANDLE OF THE FIXED CATHETER WAS CUT OFF AS IT WAS STILL ENTANGLED IN THE MAPPING CATHETER AND BOTH DEVICES WERE REMOVED VIA AN INTRODUCER.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7684831 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K894500. One submission often covers many models, so check the product and lot details in each record.
- Z-0177-2015 · Oct 14, 2014 · TerminatedSt. Jude Medical, Fixed Curve Response 6F Electrophysiology Catheter, CSL, Model 401353
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths358 reports
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death75 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page