Inquiry™ IBI-81172Recalls & reported problems
Irvine Biomedical, Inc. · Class 2
All models of Inquiry (31)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 05414734303354), received between Feb 6, 2020 and Nov 10, 2025 — classified as 3 injuries, 1 malfunction.
The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem3
- Activation, Positioning or Separation Problem1
Patient problems
- Cardiac Perforation3
- Death1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 10, 2025Activation, Positioning or Separation Problem; Activation, Positioning or Separation Problem
DURING THE SUPRAVENTRICULAR TACHYCARDIA RADIOFREQUENCY PROCEDURE, THERE WAS A DELAY. THE CATHETER COULD NOT BE INSERTED INTO THE PATIENT'S CORONARY SINUS. AFTER REMOVAL, IT WAS NOTED THAT THE TIP OF THE CATHETER WOULD NOT BEND. THE CATHETER WAS REPLACED AND THAT ISSUE WAS RESOLVED. IN ADDITION, THE SHEATH WAS BENT CLOCKWISE TO ALIGN WITH THE AXIS OF ROTATION. THE SHEATH WAS REPLACED AND THE PROCEDURE WAS COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23511467 ↗InjuryJan 7, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RELATED MFR NUMBERS: 2184149-2020-00228, 3008452825-2020-00713, 3005334138-2020-00643, 3008452825-2020-00715. THE DAY FOLLOWING AN ATRIAL FIBRILLATION PROCEDURE, THE PATIENT EXPERIENCED A PERICARDIAL EFFUSION. THE EFFUSION WAS FOUND DURING POST-PROCEDURE TRANSTHORACIC ECHOCARDIOGRAPHY PERFORMED ONE DAY AFTER THE PROCEDURE. THE LOCATION OF THE PERFORATION WAS NOT KNOWN. PERICARDIOCENTESIS WAS PERFORMED TO STABILIZE THE PATIENT. THERE WERE NO PERFORMANCE ALLEGATIONS AGAINST ANY ABBOTT DEVICE.
Patient problems: Cardiac Perforation
MAUDE report 11132770 ↗InjuryDec 22, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RELATED MANUFACTURING REF: 3008452825-2020-0723, 3008452825-2020-00724, 3005334138-2020-00646, 3008452825-2020-00725. TWO DAYS POST ATRIAL FIBRILLATION ABLATION PROCEDURE, A PERICARDIAL EFFUSION WAS NOTED VIA TRANSTHORACIC ECHOCARDIOGRAPHY. SEROHEMATIC FLUID WAS DRAINED WHICH STABILIZED THE PATIENT. THERE WERE NO PERFORMANCE ISSUES WITH ANY ABBOTT DEVICES.
Patient problems: Cardiac Perforation
MAUDE report 11060803 ↗InjuryFeb 6, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RELATED MANUFACTURER REFERENCE: 2184149-2020-00014, 3008452825-2020-00066. DURING A PREMATURE VENTRICULAR CONTRACTION PROCEDURE, A CANCELLATION, TAMPONADE AND SUBSEQUENT DEATH OCCURRED. THE CS CATHETER AND THE HIS CATHETER WERE INTRODUCED VIA THE FEMORAL VEIN INTO THE CORONARY SINUS AND AT THE HIS BUNDLE. DURING INTRODUCTION, EXCESSIVE CATHETER MOVEMENT WAS OBSERVED. A FLEXIBILITY WAS INTRODUCED VIA RETROGRADE ACCESS INTO THE AORTA, AND THE LATMAP AND A GEOMETRY OF THE LVOT WAS COLLECTED. SYSTEM REFERENCE AND RESPIRATION COMPENSATION WERE UTILIZED AND THE UPDATE RESPIRATION WAS OFF. ABLATION WAS STARTED AT THE EARLIEST POINT IN THE LVOT. DUE TO THE CATHETER MOVEMENT, THE CS 5 WAS UTILIZED FOR REFERENCE. FLOURO WAS NOT USED TO LOCATE THE CATHETERS FOLLOWING THE SHIFT. DURING PREPARATION OF CHANGING FROM ARTERIAL ACCESS TO VENOUS ACCESS THE PHYSICIAN NOTICED ABNORMAL STEERING OF THE FLEXIBILITY. FOLLOWING ABLATION IN THE LVOT, THERE WERE STILL PVCS. THE VISUALIZATION OF THE ABLATION CATHETER WAS NOT IN THE CORRECT LOCATION, AND SYSTEM REFERENCE WAS UTILIZED AND A SHIFT OCCURRED. THE CS SHADOW AND CURRENT CS POSITION WERE NOT ALIGNED. THE PHYSICIAN DECIDED TO GO IN RVOT AND A FLEXIBIL
Patient problems: Cardiac Perforation; Death
MAUDE report 9677260 ↗
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths358 reports
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death75 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page