Inquiry™ IBI-87007Recalls & reported problems
Irvine Biomedical, Inc. · Diagnostic Catheter · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05414734309912), received between Apr 10, 2020 and Apr 10, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Difficult to Remove” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Difficult to Remove1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 10, 2020Difficult to Remove; Difficult to Remove
DURING AN ATRIAL FIBRILLATION ABLATION PROCEDURE, WHEN MAPPING WAS PERFORMED IN THE LEFT ATRIUM, IT WAS FOUND THROUGH FLUOROSCOPY THAT THE PART BELOW THE LOOP OF THE CATHETER WAS KINKED. THE CATHETER WAS ATTEMPTED TO BE WITHDRAWN INTO THE SHEATH WITHOUT THE STRAIGHTENER, BUT WAS NOT SUCCESSFUL. THE KINK WAS ATTEMPTED TO BE STRAIGHTENED WITH A SNARE, BUT THE CATHETER STILL COULD NOT BE WITHDRAWN INTO THE SHEATH. THE ISSUE WAS RESOLVED AFTER THE CATHETER WAS STRAIGHTENED, ROTATED AND MANIPULATED INSIDE OF THE PATIENT. THE CATHETER WAS THEN WITHDRAWN INTO THE SHEATH AND REMOVED FROM THE PATIENT. UPON INSPECTION THE CATHETER WAS FOUND TO BE KINKED BUT NO OTHER DAMAGE WAS NOTED. THE PROCEDURE WAS COMPLETED BY USING ANOTHER CATHETER AND THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9947756 ↗
Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices
- Advisor™ HD Grid, Sensor Enabled™ D-AVHD-DF16St. Jude Medical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths358 reports
- IntellaMap Orion™ M004RC64S0Boston Scientific Corporation · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING6 deaths356 reports
- ACHIEVE™ 990063-020Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING7 deaths129 reports
- Inquiry™ IBI-81104Irvine Biomedical, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 recall2 deaths64 reports
- DECANAV R7F282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING4 deaths108 reports
- LASSO NAV D134301Biosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING2 deaths82 reports
- DECANAV R7D282CTBiosense Webster Inc · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING1 death75 reports
- ACHIEVE ADVANCE™ 2ACH20Medtronic, Inc. · CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING3 deaths69 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.