Skip to content

ViewFlex™ H701374Recalls & reported problems

St. Jude Medical, Inc. · Catheter Interface Module · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 05415067013743), received between Jun 10, 2019 and Apr 17, 2026 — classified as 3 injuries, 6 malfunctions.

The most frequently reported specific device problem is “Communication or Transmission Problem” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Communication or Transmission Problem6
  • Detachment of Device or Device Component1
  • Display or Visual Feedback Problem1
  • Erratic or Intermittent Display1
  • Material Frayed1
  • Mechanical Problem1
  • Sparking1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6
  • No Consequences Or Impact To Patient3

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 17, 2026Material Frayed; Sparking

    WHEN THE CABLE WAS PLUGGED IN, A VISIBLE SPARK WAS NOTED. THE CABLE WAS FRAYED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24906423 ↗
  • MalfunctionJun 28, 2024Communication or Transmission Problem; Communication or Transmission Problem

    DURING A PULMONARY VEIN ISOLATION (PVI) PROCEDURE, COMMUNICATION ISSUES RESULTED IN A PROCEDURAL DELAY. IT WAS REPORTED THAT THE CIM FOR THE VIEWMATE MULTI DID NOT DISPLAY THE ICE PROBE. A DIFFERENT CIM WAS BORROWED FROM ANOTHER SITE TO COMPLETE THE PROCEDURE WHICH RESULTED IN A 2 HOUR DELAY. THE PROCEDURE WAS COMPLETED WITH NO ADVERSE CONSEQUENCES FOR THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19638666 ↗
  • MalfunctionMay 30, 2023Communication or Transmission Problem; Communication or Transmission Problem

    DURING THE START OF A PREMATURE VENTRICULAR TACHYCARDIA PROCEDURE, THE NEW CATHETER INTERFACE MODULE WAS UNABLE TO COMMUNICATE WITH THE VIEWMATE SYSTEM, WHICH RESULTED IN A DELAY. THE CATHETER AND CONSOLE WERE REPLACED WITH A NON-ABBOTT (BIOSENSE) SYSTEM AND THE PROCEDURE WAS COMPLETED WITHOUT ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17025250 ↗
  • MalfunctionMar 31, 2023Communication or Transmission Problem; Communication or Transmission Problem

    THE DELAY IS NOT A REPORTABLE EVENT. AS THIS OCCURRED DURING A LEFT ATRIAL APPENDAGE CLOSURE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16658423 ↗
  • MalfunctionJan 7, 2022Communication or Transmission Problem; Detachment of Device or Device Component; Communication or Transmission Problem; Detachment of Device or Device Component

    DURING AN ATRIAL FIBRILLATION ABLATION PROCEDURE, THE CATHETER INTERFACE MODULE (CIM) WOULD NOT RECOGNIZE THE ICE CATHETER AND THE PROCEDURE WAS CANCELLED AS A RESULT. THE CATHETER WAS INITIALLY REPLACED, BUT THE ISSUE REMAINED. A RATTLING SOUND WAS NOTED TO BE COMING FROM WITHIN THE CIM. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 13192769 ↗
  • MalfunctionApr 23, 2021Communication or Transmission Problem; Communication or Transmission Problem

    DURING A CRYO ATRIAL FIBRILLATION ABLATION PROCEDURE, THE CIM DID NOT RECOGNIZE THE CATHETERS. A TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE) WAS PERFORMED INSTEAD WITH ANESTHESIA ADMINISTERED TO COMPLETE THE PROCEDURE SUCCESSFULLY WITH NO CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11715358 ↗
  • InjuryMay 15, 2020Communication or Transmission Problem; Communication or Transmission Problem

    DURING A PROCEDURE, THE CATHETER INTERFACE MODULE (CIM) WOULD NO LONGER RECOGNIZE THE PROBES. THE PATIENT WAS ALREADY PREPARED WHEN THE PROCEDURE WAS CANCELLED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10060771 ↗
  • InjuryDec 30, 2019Display or Visual Feedback Problem; Mechanical Problem; Display or Visual Feedback Problem; Mechanical Problem

    DURING A CRYO ATRIAL FIBRILLATION PROCEDURE, A RATTLING NOISE WAS HEARD WITHIN THE CIM AND THE UNIT DISPLAYED DARK IMAGES SO THE PROCEDURE WAS CANCELLED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT DUE TO THE CANCELLATION.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9530630 ↗
  • InjuryJun 10, 2019Erratic or Intermittent Display; Erratic or Intermittent Display

    DURING A PROCEDURE, THE IMAGE WAS POOR WHEN THE ICE CATHETER WAS IN USE. DIFFERENT CATHETERS WERE USED BUT THE ISSUE REMAINED. AS NO REPLACEMENT CATHETER INTERFACE MODULE (CIM) WAS AVAILABLE, THE PROCEDURE WAS CANCELLED. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8683609 ↗