Skip to content

Advisor™ D-AVSE-D10-F15Recalls & reported problems

St. Jude Medical, Inc. · FL, Sensor Enabled Circular Mapping Catheter · Class 2

All models of Advisor (4)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
13
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 05415067024800), received between Feb 1, 2019 and Feb 11, 2025 — classified as 3 injuries, 10 malfunctions.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 3 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 1 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture4
  • Adverse Event Without Identified Device or Use Problem2
  • Material Deformation2
  • Detachment of Device or Device Component1
  • Difficult to Insert1
  • Expiration Date Error1
  • Material Integrity Problem1
  • Material Rupture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Cardiac Perforation2
  • No Consequences Or Impact To Patient2
  • Thrombosis/Thrombus1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 11, 2025Fracture; Fracture

    THIS REPORT IS TO ADVISE OF A FRACTURE THAT WAS NOTED DURING ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21356744 ↗
  • MalfunctionJul 26, 2024Fracture; Material Deformation; Fracture; Material Deformation

    THIS REPORT IS TO ADVISE OF A FRACTURE AND DISPLACED ELECTRODES FOUND ON THE CATHETER DURING ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19840967 ↗
  • MalfunctionFeb 26, 2024Signal Artifact/Noise; Expiration Date Error; Signal Artifact/Noise; Expiration Date Error

    ADDITIONAL INFORMATION RECEIVED ON 3/28/24 CONFIRMED THE CORRECT LOT NUMBER IS 8622315 AND THE CORRECT EVENT DATE WAS OCTOBER 21, 2023. THE EXPIRATION DATE OF THIS LOT WAS JANUARY 31, 2024 AND WAS THEREFORE NOT EXPIRED AT THE TIME OF USE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18778608 ↗
  • MalfunctionFeb 16, 2024Fracture; Fracture

    THIS REPORT IS TO ADVISE OF CATHETER FRACTURES NOTED DURING ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18722192 ↗
  • MalfunctionFeb 1, 2024Material Deformation; Material Deformation

    THIS REPORT IS TO ADVISE OF A DISPLACED ELECTRODE FOUND DURING ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18625574 ↗
  • InjuryJan 19, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DURING AN ATRIAL FIBRILLATION PROCEDURE, A PERICARDIAL EFFUSION OCCURRED REQUIRING A PERICARDIOCENTESIS. AFTER LEFT PULMONARY VEIN ISOLATION THE PATIENT BECAME HYPOTENSIVE. AN ECHOCARDIOGRAPHY CONFIRMED A PERICARDIAL EFFUSION AROUND THE RIGHT AND LEFT HEART CAVITIES. THE PROCEDURE WAS STOPPED, AND THE PERICARDIAL EFFUSION WAS DRAINED BY PERCUTANEOUS PUNCTURE, WHICH STABILIZED THE PATIENT. IT IS UNKNOWN WHAT CAUSED THIS PERICARDIAL EFFUSION.

    Patient problems: Cardiac Perforation

    MAUDE report 18547465 ↗
  • MalfunctionDec 23, 2022Fracture; Fracture

    DURING AN ATRIAL FIBRILLATION PROCEDURE, ONCE POSITIONED ON THE SEPTUM TO PERFORM THE TRANSSEPTAL PUNCTURE, A FRACTURE WAS NOTED ON THE SHAFT OF THE DEVICE. THE DEVICE WAS REPLACED AND THE PROCEDURE WAS COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16043370 ↗
  • MalfunctionApr 5, 2022Material Integrity Problem; Material Integrity Problem

    THIS REPORT IS TO ADVISE OF A DISPLACED AND FLARED ELECTRODE NOTED DURING DEVICE ANALYSIS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14013925 ↗
  • MalfunctionAug 4, 2021Difficult to Insert; Difficult to Insert

    THIS REPORT IS TO ADVISE OF AN EVENT OBSERVED DURING ANALYSIS CONFIRMING A DISPLACED ELECTRODE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12274110 ↗
  • InjuryJul 19, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DURING THE PROCEDURE, AFTER MAPPING THE PAROXYSMAL ATRIAL FIBRILLATION IN THE LEFT ATRIUM, THE PATIENT BECAME HYPOTENSIVE AND A PERICARDIAL EFFUSION WAS DIAGNOSED VIA ULTRASOUND. THE ISOLATION OF THE FOUR PULMONARY VEINS WAS CARRIED OUT AND THEN THE PATIENT WAS STABILIZED BY CONDUCTING A PERICARDIOCENTESIS. THERE WERE NO PERFORMANCE ISSUES WITH THE DEVICE.

    Patient problems: Cardiac Perforation

    MAUDE report 12188533 ↗
  • InjuryJun 3, 2021Patient Device Interaction Problem; Patient Device Interaction Problem

    DURING AN ATRIAL FIBRILLATION ABLATION PROCEDURE, AFTER CONDUCTING THE TRANSSEPTAL PUNCTURE, THE PHYSICIAN SUSPECTED THERE WAS A CLOT ON THE MAPPING CATHETER WHEN USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY. THE PROCEDURE WAS CONTINUED WITH ONLY USING THE ABLATION CATHETER FOR MAPPING AND ABLATION AND THE MAPPING CATHETER WAS NOT MOVED. A BOLUS OF HEPARIN WAS DELIVERED AND THE PROCEDURE WAS ABLE TO BE COMPLETED WITH NO ADVERSE CONSEQUENCES TO THE PATIENT. BOTH THE ABLATION AND MAPPING CATHETER WERE REMOVED USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND NO CLOTS WERE OBSERVED. THE PHYSICIAN SUSPECTED THE CLOT WAS FROM THE RIGHT ATRIUM AND WENT INTO THE LEFT ATRIUM WHEN THE TRANSSEPTAL PUNCTURE WAS CONDUCTED.

    Patient problems: Thrombosis/Thrombus

    MAUDE report 11929162 ↗
  • MalfunctionAug 21, 2020Material Rupture; Material Rupture

    DURING THE PROCEDURE, ELECTRODE ONE RUPTURED WHILE BEING REMOVED FROM THE INTRODUCER. ANOTHER CATHETER WAS USED TO CONTINUE THE PROCEDURE WITH NO CONSEQUENCES TO THE PATIENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10437136 ↗
  • MalfunctionFeb 1, 2019Detachment of Device or Device Component; Detachment of Device or Device Component

    THIS REPORT IS TO ADVISE OF AN EVENT OBSERVED DURING ANALYSIS CONFIRMING A SEPARATED ELECTRODE ON THE CATHETER.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8296927 ↗

FDA clearance and classification

Cleared through 510(k) K202066 on Nov 25, 2020 (decision: Substantially Equivalent). Submitted by Abbott Medical as “EnSite X EP System, Advisor VL Circular Mapping Catheter, Sensor Enabled, Advisor FL Circular Mapping Catheter, Sensor Enabled, Advisor HD Grid High Density Mapping Catheter, Senor Enabled”. The FDA review took 121 days. FDA record ↗

Cleared through 510(k) K160335 on Dec 13, 2016 (decision: Substantially Equivalent). Submitted by St Jude Medical as “Advisor FL 15mm 12 Pole 333 Uni D, Advisor FL 20mm 12 Pole 555 Uni D, Advisor FL 15mm 12 Pole 333 Bi D, Advisor FL 20mm 12 Pole 555 Bi D”. The FDA review took 309 days. FDA record ↗

The FDA regulates product code DRF (catheter, electrode recording, or probe, electrode recording) under 21 CFR 870.1220 as a Class II device. 21 CFR 870.1220 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Advisor™ D-AVSE-D10-F15

Has the Advisor™ D-AVSE-D10-F15 been recalled?

No FDA recall record in our data names this exact device identifier (DI 05415067024800), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Advisor™ D-AVSE-D10-F15?

The FDA's MAUDE database lists 13 adverse event reports for this device, received between Feb 1, 2019 and Feb 11, 2025. In those reports, the most common specific device problems are “Fracture” (4), “Material Deformation” (2) and “Detachment of Device or Device Component” (1); the most common patient problems are “Cardiac Perforation” (2) and “Thrombosis/Thrombus” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Advisor™ D-AVSE-D10-F15?

None of the reports are classified as deaths, 3 as injuries and 10 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Advisor™ D-AVSE-D10-F15 FDA approved?

It was cleared through 510(k) K160335 on Dec 13, 2016; its record lists 2 FDA submissions in total. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Advisor™ D-AVSE-D10-F15, and is it still sold?

The FDA's device database lists St. Jude Medical, Inc. as the company responsible for it (brand Advisor™, model D-AVSE-D10-F15). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices

All CATHETER, ELECTRODE RECORDING, OR PROBE, ELECTRODE RECORDING devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page