Agilis HisPro™ DS3H010-38Recalls & reported problems
St. Jude Medical, Inc. · Steerable Catheter with Electrodes · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 1
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05415067032287), received between May 19, 2022 and Jan 9, 2023 — classified as 1 death, 1 injury.
The most frequently reported specific device problem is “Activation, Positioning or Separation Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Activation, Positioning or Separation Problem1
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Cardiac Perforation1
- Hemorrhage/Blood Loss/Bleeding1
- Low Blood Pressure/ Hypotension1
- Perforation of Vessels1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJan 9, 2023Activation, Positioning or Separation Problem; Activation, Positioning or Separation Problem
RELATED MANUFACTURING REFERENCE NUMBER: 2017865-2023-00728. IT WAS REPORTED THAT THE PATIENT PRESENTED FOR AN IMPLANT PROCEDURE. DURING THE PROCEDURE, IT WAS NOTED THAT THE RIGHT VENTRICULAR LEAD PERFORATED THE LEFT VENTRICLE. THE PHYSICIAN ALLEGED THAT THE PERFORATION WAS CAUSED BY THE HIGH PULL BACK STRENGTH OF THE CATHETER. THE LEAD WAS REPOSITIONED SUCCESSFULLY. NO FURTHER INTERVENTION WAS PERFORMED. THE PATIENT WILL CONTINUE TO BE MONITORED. THERE WERE NO PATIENT CONSEQUENCES.
Patient problems: Cardiac Perforation
MAUDE report 16127189 ↗DeathMay 19, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
RELATED MANUFACTURER REPORT NUMBER: 2017865-2022-10397, 2017865-2022-10398. DURING A DEVICE UPGRADE PROCEDURE, THE TENDRIL LEAD WAS ATTEMPTED TO BE IMPLANTED USING THE HISPRO CATHETER. AN ACCEPTABLE IMPLANT POSITION COULD NOT BE FOUND, SO A NEW APPROACH WAS ATTEMPTED WITH A CPS DIRECT UNIVERSAL CATHETER. LEAD PLACEMENT WAS AGAIN UNSUCCESSFUL, SO THE HISPRO CATHETER WAS AGAIN ATTEMPTED. AT THIS TIME, A DROP IN BLOOD PRESSURE OCCURRED WHICH WAS SUCCESSFULLY RESOLVED WITH MEDICATION. LEAD PLACEMENT WAS AGAIN ATTEMPTED BEFORE THE PHYSICIAN ELECTED TO ABORT THE IMPLANT PROCEDURE AND REMOVE THE HISPRO CATHETER. THE PATIENT'S BLOOD PRESSURE AGAIN DROPPED, HOWEVER, MEDICATION WAS UNSUCCESSFUL. CARDIOPULMONARY RESUSCITATION (CPR) WAS INITIATED AND MAINTAINED FOR 15 MINUTES. CHEST DRAINAGE WAS PERFORMED WHICH REVEALED BLEEDING AND A HEMOTHORAX. CPR WAS STOPPED AND THE PATIENT WAS PRONOUNCED DECEASED. THE PHYSICIAN SUSPECTED A PERFORATION OF THE SUPERIOR VENA CAVA OCCURRED EARLY IN THE PROCEDURE WHEN ACCESSING THE SUBCLAVIAN VEIN SYSTEM. THE PHYSICIAN DID NOT ALLEGE A MALFUNCTION ON ANY ABBOTT PRODUCT, NOR DID THEY ALLEGE ANY ABBOTT PRODUCT DIRECTLY CAUSED OR CONTRIBUTED TO THE PATIENT'S PASS
Patient problems: Hemorrhage/Blood Loss/Bleeding; Low Blood Pressure/ Hypotension; Perforation of Vessels
MAUDE report 14434637 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page