Masters Series™ 21AHPJ-505Recalls & reported problems
St. Jude Medical, Inc. · HP Mechanical Heart Valve · Class 3 · Implant
All models of Masters Series (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05415067043597), received between Jul 6, 2023 and Oct 20, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Physical Resistance/Sticking” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Physical Resistance/Sticking2
- Detachment of Device or Device Component1
- Device Stenosis1
- Fracture1
- Incomplete Coaptation1
Patient problems
- No Clinical Signs, Symptoms or Conditions5
- Aortic Valve Stenosis1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 20, 2025Incomplete Coaptation; Incomplete Coaptation
IT WAS REPORTED THAT ON (B)(6) 2025, A 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS CHOSEN FOR A PROCEDURE. DURING PROCEDURE, THE VALVE WAS INSTALLED AND CHECKED THE VALVE FUNCTION USING VALVE TESTERS. IT WAS NOTED THAT THE VALVE WAS NOT FUNCTIONING COMPLETELY. THE VALVE OPENED VERY SLOWLY AND DID NOT RETRACT. A NEW 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS CHOSEN AND IMPLANTED SUCCESSFULLY. AFTER THE PROCEDURE, THE PATIENT WAS HEMODYNAMICALLY STABLE. TWO DAYS AFTER THE PROCEDURE, THE PATIENT WAS REPORTED PASSED AWAY. THE PHYSICIAN MENTIONED THE PATIENT DIED DUE TO HIS HEALTH CONDITION PRIOR TO SURGERY. THE CAUSE OF DEATH WAS HEART FAILURE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23337294 ↗MalfunctionJul 11, 2025Fracture; Fracture
MalfunctionJan 7, 2025Detachment of Device or Device Component; Detachment of Device or Device Component
IT WAS REPORTED THAT ON (B)(6) 2024, A 21MM MASTERS AORTIC MECHANICAL HEART VALVE WAS SELECTED FOR IMPLANT. DURING PROCEDURE, A LEAFLET SUSTAINED DAMAGE; A SMALL FRAGMENT OF THE LEAFLET FRACTURED NEAR THE COSTING EDGE OF THE LEAFLET. NO INSTRUMENTS WERE IN CONTACT WITH THE VALVE AT THE TIME THE FRACTURE WAS OBSERVED. NO RESISTANCE WAS FELT WHEN ROTATING. IT WAS EXCHANGED FOR A NEW 19MM MASTERS AORTIC MECHANICAL HEART VALVE, WHICH WAS SUCCESSFULLY IMPLANTED. THE PATIENT WAS REPORTED TO BE IN STABLE CONDITION. OF NOTE, THE PATIENT UNDERWENT A DOUBLE VALVE REPLACEMENT AND AN UNKNOWN SIZED VALVE WAS IMPLANTED INTO THE MITRAL SIDE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21096013 ↗MalfunctionOct 25, 2023Physical Resistance/Sticking; Device Stenosis; Physical Resistance/Sticking; Device Stenosis
IT WAS REPORTED THAT ON (B)(6) 2023, A 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS CHOSEN FOR IMPLANT. AFTER THE VALVE WAS SUTURED IN, NORMAL LEAFLET FUNCTION WAS CONFIRMED MANUALLY WITH THE OFFICIAL LEAFLET TESTER. AFTER PROCEDURE, THE PATIENT PASSED A SMOOTH POST-OPERATIVE COURSE. THREE DAYS POST-PROCEDURE, IT WAS OBSERVED DURING PRE-DISCHARGE TRANSTHORACIC ECHOCARDIOGRAPHY (TTE) THE VALVE LEAFLET WAS STUCK IN OPEN POSITION. THIS WAS CONFIRMED THE NEXT DAY ON TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE). IT WAS NOTED THAT THE PRESSURE GRADIENT WAS HIGH, WHICH WAS BELIEVED TO BE DUE TO THE IMPLANTED VALVE. A DECISION WAS MADE TO EXPLANT THE VALVE ON (B)(6) 2023 AND REPLACED WITH ANOTHER 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE. THE EXPLANTED VALVE WAS TESTED AGAIN FOR LEAFLET FUNCTION AND FOUND TO MOVE NORMALLY WITH THE LEAFLET TESTER BUT AFTER A FEW MINUTES THE LEAFLET WAS STUCK AGAIN AND NEEDED THE LEAFLET TESTER TO PUSH. THE PATIENT REMAINED HEMODYNAMICALLY STABLE THROUGHOUT THE PROCEDURE. THE PATIENT STATUS WAS REPORTED AS DISCHARGED. 10 DAYS POST-PROCEDURE, THE PATIENT PRESENTED WITH INFECTIVE ENDOCARDITIS ON THE SECOND 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE. T
Patient problems: Aortic Valve Stenosis; No Clinical Signs, Symptoms or Conditions
MAUDE report 18007722 ↗MalfunctionJul 6, 2023Physical Resistance/Sticking; Physical Resistance/Sticking
IT WAS REPORTED THAT ON (B)(6) 2023 A 21MM SJM MASTERS SERIES MECHANICAL HEART VALVE WAS SELECTED FOR AN IMPLANT. POST PROCEDURE, STILL IN PROCEDURE ROOM, IT WAS OBSERVED THAT ONE LEAFLET DID NOT OPEN CONSISTENTLY. DEVICE WAS REPLACED WITH A NEW 21MM SJM MASTERS SERIES MECHANICAL HEART VALVE THAT WAS SUCCESSFULLY IMPLANTED. THE PATIENT IS STABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17269338 ↗
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page