Masters Series™ 19MHPJ-505Recalls & reported problems
St. Jude Medical, Inc. · HP Mechanical Heart Valve · Class 3 · Implant
All models of Masters Series (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05415067043719), received between Jun 9, 2025 and Jun 9, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture1
- Patient-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJun 9, 2025Fracture; Patient-Device Incompatibility; Fracture; Patient-Device Incompatibility
IT WAS REPORTED THAT ON 15 DEC. 2014, A 19MM MASTERS MITRAL VALVE WAS SELECTED FOR IMPLANT. ON (B)(6) 2025, IT WAS NOTED THAT THERE WAS A GENERAL NARROWING OF THE VALVE AS THE PATIENT GREW, SO IT WAS DECIDED TO REPLACE THE VALVE. DURING THE REMOVAL OF THE MECHANICAL VALVE, ONE OF THE LEAFLETS BECAME DAMAGED AND FRAGMENTS FELL INTO THE LEFT VENTRICLE. MOST OF THE FRAGMENTS WERE RETRIEVED, BUT A FEW SAND-SIZED PIECES COULD NOT BE FOUND. THE LEFT VENTRICLE WAS WASHED WITH 2 LITERS OF SALINE. AFTER THAT, THE LEFT VENTRICLE WAS CHECKED AGAIN TO CONFIRM THAT THERE WERE NO FRAGMENTS. AN X-RAY WAS TAKEN, BUT NO FRAGMENTS WERE FOUND. THE DEVICE WAS REPLACED WITH AN 25MM MASTERS VALVE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22171176 ↗
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page