Masters Series™ 21MHPJ-505Recalls & reported problems

St. Jude Medical, Inc. · Mechanical Heart Valve · Class 3 · Implant

All models of Masters Series (28)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05415067043733), received between Feb 29, 2024 and Feb 29, 2024 — classified as 1 injury.

The most frequently reported specific device problem is “Off-Label Use” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Off-Label Use1
  • Perivalvular Leak1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 29, 2024Perivalvular Leak; Off-Label Use; Perivalvular Leak; Off-Label Use

    IT WAS REPORTED THAT ON (B)(6) 2024, A 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS CHOSEN FOR IMPLANT IN THE TRICUSPID POSITION. DURING PROCEDURE, THE PHYSICIAN USED AN EVERTING MATTRESS TECHNIQUE WITH PLEDGETS ON THE ATRIAL SIDE AND ORIENTED THE VALVE IN AN ANTI-ANATOMICAL POSITION. AFTER SUTURING THE VALVE, THE PHYSICIAN CHECKED FOR LEAFLET MOTION WITH A Q TIP AND WAS SATISFIED. THE BYPASS WAS TURNED OFF, BUT THE ECHOCARDIOGRAM SHOWED A MODERATE PERIVALVULAR LEAK (PVL). THE PHYSICIAN WAS VERY FAMILIAR WITH THE JET'S ASSOCIATED WITH OUR LEAFLET DESIGN, BUT THIS LOOKED DIFFERENT TO HIM, THE PATTERN OF THE JET DESIGN WAS NOT CENTRAL BUT EXTERNAL IN NATURE. A DECISION WAS MADE TO REPLACE THE VALVE AND THE PHYSICIAN TURNED ON THE BYPASS. A NEW 21MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS CHOSEN AND IMPLANTED USING THE SAME TECHNIQUE BUT THEY ORIENTED THE VALVE 45 DEGREE'S FROM THE ORIGINAL ORIENTATION. THE PHYSICIAN TURNED OFF THE BYPASS AND AN ECHO WAS PERFORMED, NO PERIVALVULAR LEAK (PVL) WAS NOTED. THERE WAS NO REPORTED CONSEQUENCES TO THE PATIENT. THE PATIENT REMAINED HEMODYNAMICALLY STABLE THROUGHOUT THE PROCEDURE. THERE WAS NO CLINICALLY SIGNIFICANT DELAY IN PROCEDU

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18808985 ↗