Masters Series™ 25CAVGJ-514 00Recalls & reported problems
St. Jude Medical, Inc. · Aortic Valved Graft with Hemashield Graft technology Mechanical Valved Graft · Class 3 · Implant
All models of Masters Series (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 05415067044099), received between Mar 4, 2024 and Mar 18, 2025 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Contamination /Decontamination Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Contamination /Decontamination Problem2
- Physical Resistance/Sticking2
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 18, 2025Physical Resistance/Sticking; Physical Resistance/Sticking
IT WAS REPORTED THAT ON (B)(6) 2025, A 25MM MASTERS SERIES MECHANICAL HEART VALVE WAS SELECTED FOR IMPLANT. DURING DEVICE PREPARATION, THE LEAFLETS WERE MOVING NORMALLY. AFTER THE VALVE WAS IMPLANTED AND SUTURING WAS COMPLETED, THE HEART STARTED BEATING AGAIN. HOWEVER, THIS WAS "ACCOMPANIED BY THE PROBLEM OF BLOCKING THE HEART VALVE." THE VALVE WAS UNABLE TO BE ROTATED AFTER IMPLANTATION; THE LEAFLETS WERE NOT OPENING AND CLOSING. THE CAUSE OF THE INABILITY TO ROTATE WAS REPORTED AS "THE MECHANICAL VALVE IS STUCK." A VALVE MEASURING DEVICE WAS USED TO TEST THE LEAFLET FUNCTION. THE VALVE WAS EXPLANTED AND UPON EXPLANT, THE LEAFLET MOVEMENT WAS TESTED AGAIN WITH NORMAL MOBILITY. IT WAS EXCHANGED FOR A NEW 23MM MASTERS SERIES HEART COATED AORTIC VALVED GRAFT, WHICH WAS SUCCESSFULLY IMPLANTED. THE PATIENT WAS REPORTED TO BE IN IN GOOD CONDITION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21635063 ↗MalfunctionDec 13, 2024Contamination /Decontamination Problem; Physical Resistance/Sticking; Contamination /Decontamination Problem; Physical Resistance/Sticking
IT WAS REPORTED THAT ON (B)(6) 2024, A 25MM SJM MASTERS SERIES COATED AORTIC VALVED GRAFT WAS SELECTED FOR IMPLANT. DURING THE PROCEDURE, WHILE SUTURING THE VALVE, THE PHYSICIAN NOTICED STAINS ON THE AORTIC VALVE GRAFT TUBE. THE DEVICE WAS REMOVED AND REPLACED. IT WAS ALSO NOTED THAT THE LEAFLETS DIDN'T OPEN AND CLOSE SMOOTHLY. THERE WERE NO ADVERSE HEALTH CONSEQUENCES TO THE PATIENT. THE PATIENT REMAINED HEMODYNAMICALLY STABLE THROUGHOUT THE PROCEDURE AND THERE WAS NO CLINICALLY SIGNIFICANT DELAY. THE PATIENT HAS BEEN DISCHARGED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20929042 ↗MalfunctionMar 4, 2024Contamination /Decontamination Problem; Contamination /Decontamination Problem
IT WAS REPORTED THAT ON (B)(6)2024, A 25MM SJM MASTERS SERIES COATED AORTIC VALVED GRAFT WAS CHOSEN FOR A BENTALL PROCEDURE. DURING PROCEDURE, AFTER THE ANASTOMOSIS OF THE DEVICE, THE PHYSICIAN FOUND LARGE AMOUNT OF YELLOW DOTS INSIDE THE CONDUIT. THERE WAS NO ANOMALIES WERE FOUND DURING PREPARATION. THE PHYSICIAN DECIDED NOT TO EXPLANT THE DEVICE AND TRIED TO REMOVE THEM ONE BY ONE. WHEN THE BLOOD FLOW WAS RESTORED HE REPORTED A LOST OF IMPERMEABILITY OF THE CONDUIT, THE INITIAL LOSS OF BLOOD FROM THE TISSUE WAS RESOLVED AFTER SOME MINUTES. THE PATIENT REMAINED HEMODYNAMICALLY STABLE THROUGHOUT THE PROCEDURE. THERE WAS NO CLINICALLY SIGNIFICANT DELAY IN PROCEDURE AND NO ADVERSE PATIENT EFFECTS. THE PATIENT WAS REPORTED STABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18828841 ↗
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page