SureClip(®) Repositionable Hemostasis Clip ROCC-D-26-235-C-NRecalls & reported problems
Micro-Tech (Nanjing) Co., Ltd. · Open width11±1mm the max OD of insertion part 2.6mm working length 2350mm coated, Full Rotation wire · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 06932503530446), received between Jun 11, 2025 and Jun 20, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Difficult to Advance” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Advance1
- Firing Problem1
- Unintended Movement1
Patient problems
- Gastrointestinal Hemorrhage2
- Embolism/Embolus1
- Stomach Ulceration1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 20, 2025Unintended Movement; Firing Problem; Unintended Movement; Firing Problem
IT WAS REPORTED THAT PATIENT PRESENTED TO ENDOSCOPY DEPARTMENT AS A TRANSFER FROM INTENSIVE CARE FOR AN EGD [ESOPHAGOGASTRODUODENOSCOPY] COLONOSCOPY FOR GIB [GASTROINTESTINAL BLEEDING]. UPON ENTERING STOMACH WITH ENDOSCOPE, PATIENT'S STOMACH WAS FOUND TO CONTAIN OLD BLOOD AND FOOD DEBRIS, WHICH WERE REMOVED. UPON ADVANCING FURTHER, PATIENT'S DUODENAL BULB WAS FOUND TO CONTAIN A LARGE ULCER WITH A VISIBLE BLOOD VESSEL (NOT ACTIVELY BLEEDING). EPINEPHRINE WAS INJECTED INTO ULCER, FOLLOWED BY ELECTROCAUTERY BEING ADMINISTERED. ONE HEMOSTASIS CLIP WAS DEPLOYED WITH NO PROBLEM, BUT THE SECOND CLIP MIS-DEPLOYED. AFTER THIS, BLOOD BEGAN TO STREAM OUT OF ULCER. VARIOUS METHODS OF TREATMENT WERE USED UNTIL HEMOSTASIS WAS ACHIEVED. GI CALLED CVIR [CARDIOVASCULAR INTERVENTIONAL RADIOLOGY] DEPARTMENT TO ALERT THEM OF SITUATION AND MAKE SURE THEY WERE READY TO TAKE PATIENT FOR EMBOLIZATION. PATIENT REMAINED INTUBATED AND WAS TRANSPORTED FROM ENDOSCOPY TO CVIR WITH THIS RN, ANESTHESIA RESIDENT.
Patient problems: Gastrointestinal Hemorrhage
MAUDE report 22295899 ↗MalfunctionJun 11, 2025Difficult to Advance
PATIENT PRESENTED TO ENDOSCOPY DEPARTMENT AS A TRANSFER FROM INTENSIVE CARE FOR AN EGD [ESOPHAGOGASTRODUODENOSCOPY] COLONOSCOPY FOR GIB [GASTROINTESTINAL BLEEDING]. UPON ENTERING STOMACH WITH ENDOSCOPE, PATIENT'S STOMACH WAS FOUND TO CONTAIN OLD BLOOD AND FOOD DEBRIS, WHICH WERE REMOVED. UPON ADVANCING FURTHER, PATIENT'S DUODENAL BULB WAS FOUND TO CONTAIN A LARGE ULCER WITH A VISIBLE BLOOD VESSEL (NOT ACTIVELY BLEEDING). EPINEPHRINE WAS INJECTED INTO ULCER, FOLLOWED BY ELECTROCAUTERY BEING ADMINISTERED. ONE HEMOSTASIS CLIP WAS DEPLOYED WITH NO PROBLEM, BUT THE SECOND CLIP MIS-DEPLOYED. AFTER THIS, BLOOD BEGAN TO STREAM OUT OF ULCER. VARIOUS METHODS OF TREATMENT WERE USED UNTIL HEMOSTASIS WAS ACHIEVED. GI CALLED CVIR [CARDIOVASCULAR INTERVENTIONAL RADIOLOGY] DEPARTMENT TO ALERT THEM OF SITUATION AND MAKE SURE THEY WERE READY TO TAKE PATIENT FOR EMBOLIZATION. PATIENT REMAINED INTUBATED AND WAS TRANSPORTED FROM ENDOSCOPY TO CVIR WITH THIS RN, ANESTHESIA RESIDENT. UDI-DI NUMBER: (01)06932503530446(17)270616(10)M240617231
Patient problems: Embolism/Embolus; Gastrointestinal Hemorrhage; Stomach Ulceration
MAUDE report 22183365 ↗
Other Hemostatic Metal Clip For The Gi Tract devices
- Resolution 360 Clip M00521230Boston Scientific Corporation · Hemostatic metal clip for the GI tract3 deaths2,291 reports
- Resolution Clip M00522610Boston Scientific Corporation · Hemostatic metal clip for the GI tract1,116 reports
- Instinct G58010Cook Incorporated · Hemostatic metal clip for the GI tract1 recall1,017 reports
- Resolution 360™ ULTRA Clip M00521400Boston Scientific Corporation · Hemostatic metal clip for the GI tract3 deaths496 reports
- Instinct G18343Cook Incorporated · Hemostatic metal clip for the GI tract244 reports
- MANTIS™ Clip M00521420Boston Scientific Corporation · Hemostatic metal clip for the GI tract195 reports
- Single Use Repositionable Clip HX-202UROlympus Medical Systems Corp. · Hemostatic metal clip for the GI tract1 recall118 reports
- colonic FTRD Set 14Ovesco Endoscopy AG · Hemostatic Metal Clip For The Gi Tract2 deaths95 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026