Scoreflex NC Scoring PTCA Catheter 640-104-1URecalls & reported problems
OrbusNeich Medical (ShenZhen) Co., Ltd. · Class 3
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 06934955936463), received between Mar 8, 2024 and Mar 8, 2024 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Perforation of Vessels1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 8, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A HEAVILY CALCIFIED PROXIMAL LEFT ANTERIOR DESCENDING ARTERY (LAD) WAS THE TARGET TREATMENT AREA. FOLLOWING SHOCKWAVE INTRAVASCULAR LITHOTRIPSY (IVL) AND STENT PLACEMENT A TREK NC BALLOON WAS ADVANCED FOR POST DILATION THEN THE SCOREFLEX BALLOON WAS ADVANCED, WITH THE AID OF A NON-CSI OR ABBOTT GUIDE WIRE, AND INFLATED TO 12 ATMOSPHERE PRESSURE (ATM) AND REMOVED. OPTICAL COHERENCE TOMOGRAPHY (OCT) AND ANGIOGRAPHY WAS CHECKED AND A PERFORATION WAS OBSERVED. ANGIOPLASTY WAS PERFORMED USING NEW TREK BALLOON TO TREAT THE PERFORATION BUT WAS UNSUCCESSFUL. ECMO AND IMPELLA WERE PERFORMED AND A NEW NON-CSI OR ABBOTT GUIDE WIRE WAS ADVANCED AND A STENT WAS PLACED TO TREAT THE PERFORATION. THE PATIENT WAS STABLE AND TRANSFERRED TO A DIFFERENT FACILITY FOR BYPASS SURGERY. THE PHYSICIAN'S OPINION WAS THE PATIENT'S HEAVILY CALCIFIED ARTERY WAS A FRACTURE AS TO WHY THE PERFORATION OCCURRED BUT COULD NOT SAY WHICH ONE DEVICE CAUSED OR CONTRIBUTED TO THE PERFORATION. IT WAS NOTED THAT THE VESSEL WAS NOT PREPPED PROPERLY BY USING AN OVERSIZED STENT.
Patient problems: Perforation of Vessels
MAUDE report 18865543 ↗
Other Catheter, Percutaneous Transluminal Coronary Angioplasty (Ptca), Cutting/Scoring devices
- Wolverine Coronary Cutting Balloon H74939401103000Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring1 death36 reports
- Wolverine Coronary Cutting Balloon H74939401103500Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring21 reports
- Wolverine Coronary Cutting Balloon H74939401153000Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring19 reports
- Wolverine Coronary Cutting Balloon H74939401153500Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring19 reports
- Wolverine Coronary Cutting Balloon H74939401104000Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring19 reports
- Wolverine Coronary Cutting Balloon H74939401102500Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring16 reports
- Wolverine Coronary Cutting Balloon H74939401154000Boston Scientific Corporation · Catheter, percutaneous transluminal coronary angioplasty (ptca), cutting/scoring15 reports
- AngioSculpt PTCA RX Scoring Balloon Catheter 2200-3010Spectranetics Corporation · Catheter, Percutaneous Transluminal Coronary Angioplasty (Ptca), Cutting/Scoring2 deaths14 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page