Sapphire II Pro 220-203-5UURecalls & reported problems

OrbusNeich Medical (ShenZhen) Co., Ltd. · Balloon Dilatation Catheter · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 06934955942198), received between Mar 26, 2026 and Mar 26, 2026 — classified as 2 injuries.

The most frequently reported specific device problem is “Material Separation” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Separation2

Patient problems

  • Foreign Body In Patient2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 26, 2026Material Separation

    IT WAS REPORTED THAT A SAPPHIRE II BALLOON CAME APART AT DISTAL AREA OF BALLOON. FIRST ADDITIONAL INFORMATION WAS RECEIVED ON 03/04/2026: 1. PROVIDE A DETAILED SUMMARY OF EVENT FROM BEGINNING TO END, INCLUDING TROUBLESHOOTING AND RESOLUTION. - WAITING ON EMAIL FROM HOSPITAL. 2. ANATOMICAL INFORMATION? (VESSEL / LOCATION / TORTUOSITY / CALCIFICATION / STENOSIS % / ETC.) - UNKNOWN. 3. PLEASE PROVIDE PATIENT DEMOGRAPHICS (GENDER, AGE, WEIGHT, RACE, ETHNICITY) AND COMORBIDITIES. IF UNAVAILABLE, PLEASE PROVIDE REASON WHY (E.G. HOSPITAL PRIVACY POLICY) - I THOUGHT I CHOSE THE HOSPITAL PRIVATE POLICY. 4. DID THE BALLOON BECOME FULLY DETACHED OR WAS IT DAMAGED INTACT? - IT LOOKS LIKE IT'S DETACHED. 5. HOW WAS THE BALLOON FRAGMENT(S) REMOVED FROM THE PATIENT? - HE REMAINS WITH A WALL STENT COVERING. 6. IF FRAGMENT(S) REMAIN IN VIVO - DOES THE PHYSICIAN HAVE ANY CONCERNS ABOUT POTENTIAL LONG-TERM RISK OUTCOMES? - THE HOSPITAL SHOULD BE SENDING INFORMATION. 7. WHAT IS THE STATUS OF THE PATIENT? - UNKNOWN. SECOND ADDITIONAL INFORMATION WAS RECEIVED ON 3/13/2026: 1. PROVIDE A DETAILED SUMMARY OF EVENT FROM BEGINNING TO END, INCLUDING TROUBLESHOOTING AND RESOLUTION. - IT SEEMS THEY WERE USING TH

    Patient problems: Foreign Body In Patient

    MAUDE report 24696400 ↗
  • InjuryMar 26, 2026Material Separation

    IT WAS REPORTED THAT A SAPPHIRE II BALLOON CAME APART AT DISTAL AREA OF BALLOON. FIRST ADDITIONAL INFORMATION WAS RECEIVED ON 3/4/2026: 1. PROVIDE A DETAILED SUMMARY OF EVENT FROM BEGINNING TO END, INCLUDING TROUBLESHOOTING AND RESOLUTION. WAITING ON EMAIL FROM HOSPITAL. 2. ANATOMICAL INFORMATION? (VESSEL / LOCATION / TORTUOSITY / CALCIFICATION / STENOSIS % / ETC.) UNKNOWN. 3. PLEASE PROVIDE PATIENT DEMOGRAPHICS (GENDER, AGE, WEIGHT, RACE, ETHNICITY) AND COMORBIDITIES. IF UNAVAILABLE, PLEASE PROVIDE REASON WHY (E.G. HOSPITAL PRIVACY POLICY) I THOUGHT I CHOSE THE HOSPITAL PRIVATE POLICY. 4. DID THE BALLOON BECOME FULLY DETACHED OR WAS IT DAMAGED INTACT? IT LOOKS LIKE IT'S DETACHED. 5. HOW WAS THE BALLOON FRAGMENT(S) REMOVED FROM THE PATIENT? HE REMAINS WITH A WALL STENT COVERING. 6. IF FRAGMENT(S) REMAIN IN VIVO - DOES THE PHYSICIAN HAVE ANY CONCERNS ABOUT POTENTIAL LONG-TERM RISK OUTCOMES? THE HOSPITAL SHOULD BE SENDING INFORMATION. 7. WHAT IS THE STATUS OF THE PATIENT? UNKNOWN. SECOND ADDITIONAL INFORMATION WAS RECEIVED ON 3/13/2026: 1. PROVIDE A DETAILED SUMMARY OF EVENT FROM BEGINNING TO END, INCLUDING TROUBLESHOOTING AND RESOLUTION. IT SEEMS THEY WERE USING THIS IN A MINE CORON

    Patient problems: Foreign Body In Patient

    MAUDE report 24696380 ↗

Other Catheters, Transluminal Coronary Angioplasty, Percutaneous devices

All Catheters, Transluminal Coronary Angioplasty, Percutaneous devices →