TOPS™ - 30 M 85859Recalls & reported problems

Premia Spine Ltd · The TOPS™ device is a motion preserving spinal implant that is inserted into the lumbar spine via pedicle screws. The device is implanted via a posterior surgical approach to replace the degenerated skeletal elements such as the lamina and the facet joints that are removed during the decompression. · Class 3 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07290014064041), received between Jan 4, 2024 and Sep 3, 2026 — classified as 4 injuries.

The most frequently reported specific device problem is “Loose or Intermittent Connection” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Loose or Intermittent Connection1
  • Naturally Worn1
  • Use of Device Problem1

Patient problems

  • Insufficient Information2
  • Dural Tear1
  • Pain1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjurySep 3, 2026Use of Device Problem

    The company was informed about a revision case of the TOPS System in the US after more than 5 years of implantation.The original procedure was performed on (b)(6), 2021. The patient was treated with TOPS at L4-L5 as part of the US IDE clinical study.Patient experienced initial relief of pain symptoms after surgery but by Month 3 the back pain had returned and remained until her completion of the clinical study. The device remained functional for the full duration.The TOPS System was removed as part of the revision surgery and fusion was performed. During the revision procedure, the surgeon noted that the patient's disc had degenerated and was not moving in flexion/extension. The surgeon had to convert to fusion because the patient was experiencing back pain.

    Patient problems: Pain

    MAUDE report 50587191 ↗
  • InjuryFeb 20, 2026Loose or Intermittent Connection

    THE COMPANY WAS INFORMED OF A REVISION CASE OF THE TOPS SYSTEM IN THE US APPROXIMATELY TWO MONTHS POST-IMPLANTATION. THE PROCEDURE INVOLVED A DUROTOMY REPAIR AND THE REMOVAL OF A PAIN PUMP. INTRAOPERATIVELY, TWO 6.5X50MM PEDICLE SCREWS AT L5 WERE IDENTIFIED AS LOOSE; THESE WERE EXPLANTED AND REPLACED WITH 7.5X50MM SCREWS. ADDITIONALLY, TWO L4 SET SCREWS WERE REPLACED AND THE TOPS IMPLANT WAS SUBSEQUENTLY REIMPLANTED.

    Patient problems: Dural Tear

    MAUDE report 24404829 ↗
  • InjuryJun 22, 2025Naturally Worn; Naturally Worn

    THE COMPANY WAS INFORMED OF A REVISION CASE OF THE TOPS SYSTEM WITH VERSALINK IN THE UK. THE ORIGINAL PROCEDURE WAS PERFORMED ON (B)(6) 2021. ON (B)(6) 2025, THE TOPS MOTION IMPLANT AND VERSALINK RODS WERE REMOVED AND REPLACED WITH NEW IMPLANTS IN A REVISION SURGERY. THE EXPLANTS WERE NOT RETURNED FOR INVESTIGATION.

    Patient problems: Insufficient Information

    MAUDE report 22304616 ↗
  • InjuryJan 4, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE COMPANY WAS INFORMED ABOUT A REVISION CASE OF THE TOPS SYSTEM IN FRANCE. THE ORIGINAL PROCEDURE WAS PERFORMED ON (B)(6) 2022. IN THE REVISION SURGERY, WHICH WAS PERFORMED AFTER MORE THAN A YEAR, THE TOPS MOTION IMPLANT WAS REMOVED AND REPLACED WITH A NEW ONE. NO OTHER DETAILS WERE PROVIDED AND NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Insufficient Information

    MAUDE report 18441900 ↗