Rapid Medical Ltd · The Comaneci is intended for use in the neurovasculature to assist in the coil embolization of wide-necked intracranial aneurysms under fluoroscopic guidance. The Comaneci is comprised of a collapsible, fully retrievable, fine wire construction mounted on a wire shaft that expands to comply with the vessel diameter. It is delivered through a neurovascular microcatheter. The Comaneci is provided with a 3.5 French (F) peelable loading sheath. · Class 2 · Implant

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07290015107136), received between Jan 28, 2020 and Jul 1, 2024 — classified as 3 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3

Patient problems

  • Stroke/CVA2
  • Aneurysm1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 1, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE FOLLOWING EVENT WAS REPORTED IN THE SUCCESS POST-MARKET SURVEILLANCE STUDY INVOLVING A 65-YEAR-OLD MALE WITH A HISTORY OF HYPERTENSION AND MIGRAINES. HE WAS TREATED WITH THE COMANECI AND ATLAS STENT FOR A RIGHT POSTERIOR COMMUNICATING ARTERY ANEURYSM ON (B)(6) 2023. ON (B)(6) 2023, THE PATIENT EXPERIENCED LEFT UPPER EXTREMITY WEAKNESS AND DYSMETRIA, LEADING TO HOSPITAL ADMISSION. AN MRI REVEALED MULTIPLE ACUTE CEREBROVASCULAR ACCIDENT (CVA) AREAS, PREDOMINANTLY IN THE RIGHT BILATERAL WATERSHED DISTRIBUTION. THE PATIENT CONTINUED DUAL ANTIPLATELET THERAPY AND STATIN TREATMENT. NEUROLOGY SUGGESTED A LOOP RECORDER IMPLANT AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) FOR FURTHER EMBOLIC SOURCE EVALUATION. THE PATIENT UNDERWENT LINQ PLACEMENT AND TEE, WHICH SHOWED NO PATHOLOGY TO EXPLAIN THE CVA. CARDIOLOGY RECOMMENDED FOLLOW-UP IN ONE WEEK. THE PATIENT WAS DISCHARGED ON (B)(6) 2023, WITH FOLLOW-UPS SCHEDULED WITH HIS PRIMARY CARE PHYSICIAN AND CARDIOLOGY. THE EVENT WAS RESOLVED WITHOUT SEQUELAE ON JUNE 19, 2023.

    Patient problems: Stroke/CVA

    MAUDE report 19641883 ↗
  • InjuryJul 1, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE FOLLOWING EVENT WAS REPORTED IN THE SUCCESS POST-MARKET SURVEILLANCE STUDY INVOLVING A 65-YEAR-OLD MALE WITH A HISTORY OF HYPERTENSION AND MIGRAINES. HE WAS TREATED WITH THE COMANECI AND ATLAS STENT FOR A RIGHT POSTERIOR COMMUNICATING ARTERY ANEURYSM ON (B)(6) 2023. ON (B)(6) 2023, THE PATIENT EXPERIENCED LEFT UPPER EXTREMITY WEAKNESS AND DYSMETRIA, LEADING TO HOSPITAL ADMISSION. AN MRI REVEALED MULTIPLE ACUTE CEREBROVASCULAR ACCIDENT (CVA) AREAS, PREDOMINANTLY IN THE RIGHT BILATERAL WATERSHED DISTRIBUTION. THE PATIENT CONTINUED DUAL ANTIPLATELET THERAPY AND STATIN TREATMENT. NEUROLOGY SUGGESTED A LOOP RECORDER IMPLANT AND TRANSESOPHAGEAL ECHOCARDIOGRAPHY (TEE) FOR FURTHER EMBOLIC SOURCE EVALUATION. THE PATIENT UNDERWENT LINQ PLACEMENT AND TEE, WHICH SHOWED NO PATHOLOGY TO EXPLAIN THE CVA. CARDIOLOGY RECOMMENDED FOLLOW-UP IN ONE WEEK. THE PATIENT WAS DISCHARGED ON (B)(6) 2023, WITH FOLLOW-UPS SCHEDULED WITH HIS PRIMARY CARE PHYSICIAN AND CARDIOLOGY. THE EVENT WAS RESOLVED WITHOUT SEQUELAE ON JUNE 19, 2023.

    Patient problems: Stroke/CVA

    MAUDE report 19641837 ↗
  • InjuryJan 28, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    RAPID MEDICAL RECEIVED REPORT THAT COILS GOT TANGLED IN THE COMANECI EMBOLIZATION ASSIST DEVICE. THIS EVENT OCCURRED DURING A COMANECI ASSISTED COILING OF A RIGHT OPHTHALMIC ANEURYSM. THE COMANECI PERFORMED AS INTENDED, HOWEVER, COILS GOT TANGLED IN THE DEVICE. THE PHYSICIAN ATTEMPTED SEVERAL TIMES TO RELEASE THE TANGLED COILS BY OPENING AND CLOSING DEVICE MESH WITHOUT SUCCESS. THEREFORE, LVIS STENT WAS DEPLOYED DISTAL TO THE COMANECI, ONCE THE LVIS STENT WAS PLACED, THE PHYSICIAN CLOSED THE COMANECI MESH AND THE HERNIATED COILS END WERE PRESSED AGAINST THE VESSEL WALL. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITHOUT ANY FURTHER ISSUES. THE PHYSICIAN RECOGNIZED IT WAS A TECHNICAL ERROR. THE PATIENT DID NOT EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.

    Patient problems: Aneurysm

    MAUDE report 9636460 ↗

Other Temporary Coil Embolization Assist Device devices

All Temporary Coil Embolization Assist Device devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.