Auryon Atherectomy Catheter EXM-4012-H000Recalls & reported problems
Eximo Medical Ltd · Auryon Atherectomy Catheter 1.7mm - Hydrophilic Coated · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07290017590325), received between Nov 18, 2025 and Nov 18, 2025 — classified as 2 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K241553); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information2
Patient problems
- Perforation of Vessels2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryNov 18, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
LEFT PEDAL ACCESS, USED 2.0MM CATHETER IN DISTAL SFA TO DISTAL POP WITH DR. NJOH. BEFORE LASER, HE USED SHOCKWAVE AND DCB IN SFA/POP AND POBA IN TPT TO AT. AFTER THAT INITIAL TREATMENT, HE NOTICED SOME THROMBUS AND DECIDED ON 2.0 LASER CATHETER. SHEATH AND WIRE EXCHANGE OCCURRED BEFORE 2.0 INSERTION. 1 PASS AT 60 IN DISTAL SFA TO DISTAL POP- VERY SLOWLY DONE. PERFORATION IN POP RIGHT AT KNEE JOINT OCCURRED IMMEDIATELY AFTER LASER USE (PRE AND POST ANGIOGRAMS TAKEN TO PROVE).
Patient problems: Perforation of Vessels
MAUDE report 23582024 ↗InjuryNov 18, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
A CLINICAL ASSOCIATE II REPORTED AN EVENT FOR AURYON ATHERECTOMY CATHETER 1.7MM - HYDROPHILIC COATED: RIGHT PERONEAL ARTERY ACCESS, DIFFICULTY GETTING ACCESS, MULTIPLE STICKS REQUIRED. ACCESS OBTAINED, SHEATH/CATHETER/WIRE INSERTED. FOR REASONS UNKNOWN, PHYSICIAN ONLY INSERTED TIP OF SHEATH IN ARTERY. ANGIOGRAPHIC AND IVUS IMAGES OBTAINED OF R LEG, FROM CFA TO MID PERONEAL. LESIONS IDENTIFIED IN SFA, POPLITEAL, AND TPT, WITH A MINOR LESION IN DISTAL PERONEAL ARTERY, JUST BEYOND TIP OF SHEATH. IVUS MEASURED PROXIMAL PERONEAL ARTERY AT >3.0MM. DECISION MADE TO TREAT SFA, POPLITEAL, AND TPT LESIONS WITH LASER AND PTA. AURYON 1.7 LASER INSERTED, HOWEVER, IT APPEARED LASER CATHETER WOULD NOT ADVANCE IN DISTAL PERONEAL, AND IT WAS PRESUMED TO BE AT SITE OF MINOR LESION. PHYSICIAN HAD THE LASER CATHETER ACTIVATED TO GET THROUGH THE LESION (50MJ FOR APPROX. 3-5 SECONDS). LASER CATHETER ADVANCED EASILY AFTER THAT, AND TARGET LESIONS WERE TREATED WITHOUT INCIDENT. AFTER ALL TREATMENT WAS COMPLETED, ANGIOGRAPHIC IMAGES OBTAINED OF TREATMENT AREAS, AND THEN CATHETER REMOVED FOR A "SHEATH SHOT" (WIRE AND SHEATH RETAINED, FINAL IMAGING OF MID/DISTAL ARTERY BEYOND SHEATH). IMAGES DEMONSTRATED CON
Patient problems: Perforation of Vessels
MAUDE report 23582019 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K241553. One submission often covers many models, so check the product and lot details in each record.
- Z-0770-2025 · Nov 25, 2024 · Open, ClassifiedAURYON LASER SYSTEM 100-120 VAC. Model Number: EXM001. Product Number: EXM-2001-1100
Other Catheter, Peripheral, Atherectomy devices
- HawkOne™ H1-MCovidien LP · Catheter, peripheral, atherectomy1 recall367 reports
- JETSTREAM™ XC 112266-001Boston Scientific Corporation · Catheter, peripheral, atherectomy288 reports
- JETSTREAM™ XC 112264-001Boston Scientific Corporation · Catheter, peripheral, atherectomy262 reports
- SET Rotarex®S 6F 135cm (Straub Medical®) Version 1.0Straub Medical AG · Catheter, Peripheral, Atherectomy2 deaths206 reports
- SET Rotarex™S 6 F x 135 cm 80237Straub Medical AG · Catheter, Peripheral, Atherectomy1 recall79 reports
- HawkOne™ H1-SCovidien LP · Catheter, peripheral, atherectomy1 recall70 reports
- Turbo-Elite Laser Atherectomy Catheter 420-006Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls19 reports
- Turbo-Elite Laser Atherectomy Catheter 417-152Spectranetics Corporation · Catheter, Peripheral, Atherectomy2 recalls16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page