OSSIOfiber® Hammertoe Fixation System OF20025160Recalls & reported problems

Ossio Ltd · The OSSIOfiber® Hammertoe Fixation System, S, 2.5X16 mm, straight 0°. Package contains: 1 K-wire, 1 Drill-Bit, 1 Inserter, 1 Implant straight 0°. · Class 2 · Implant

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 07290017630076), received between Jan 13, 2021 and Oct 21, 2025 — classified as 4 injuries.

The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 2 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem4
  • Device Appears to Trigger Rejection2

Patient problems

  • Local Reaction2
  • Swelling/ Edema2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 21, 2025Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem; Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem

    REVISION PROCEDURE ABOUT 1 MONTH FOLLOWING HAMMERTOE FIXATION SURGERY DUE TO LOCAL INFLAMMATORY REACTION IN A PATIENT WITH RHEUMATOID ARTHRITIS.

    Patient problems: Local Reaction

    MAUDE report 23346201 ↗
  • InjuryOct 21, 2025Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem; Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem

    REVISION PROCEDURE ABOUT 1 MONTH FOLLOWING HAMMERTOE FIXATION SURGERY DUE TO LOCAL INFLAMMATORY REACTION IN A PATIENT WITH RHEUMATOID ARTHRITIS.

    Patient problems: Local Reaction

    MAUDE report 23346200 ↗
  • InjuryJan 13, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SURGEON OBSERVED SWELLING IN THE PATIENT'S FOOT AT 3 MONTH FOLLOW-UP AND REMOVED THE TWO OSSIOFIBER HAMMERTOE IMPLANTS. SURGEON REPORTED BOTH PIP FUSION SHOWED NON-UNION, WITH ONE IMPLANT PUSHED OUT AND ONE IMPLANT BROKEN IN HALF. SURGEON DRILLED OUT THE IMPLANTS AND SENT SAMPLES FOR CULTURE. HE SUBSEQUENTLY FIXATED THE TOES.

    Patient problems: Swelling/ Edema

    MAUDE report 11160615 ↗
  • InjuryJan 13, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    SURGEON OBSERVED SWELLING IN THE PATIENT'S FOOT AT 3 MONTH FOLLOW-UP AND REMOVED THE TWO OSSIOFIBER HAMMERTOE IMPLANTS. SURGEON REPORTED BOTH PIP FUSION SHOWED NON-UNION, WITH ONE IMPLANT PUSHED OUT AND ONE IMPLANT BROKEN IN HALF. SURGEON DRILLED OUT THE IMPLANTS AND SENT SAMPLES FOR CULTURE. HE SUBSEQUENTLY FIXATED THE TOES.

    Patient problems: Swelling/ Edema

    MAUDE report 11160571 ↗

Other Pin, Fixation, Smooth devices

All Pin, Fixation, Smooth devices →

Sources and updates