Skip to content

Ditron Dental ULT-08500Recalls & reported problems

Ditron Dental Ltd · Ultimate Precision Implant Ø5.0mm L8mm · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
12
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 07290109280578), received between Jul 14, 2024 and Jul 30, 2025 — classified as 12 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 2 reportsDec 2024: 4 reportsJan 2025: 3 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration7
  • Failure to Osseointegrate4
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Inadequate Osseointegration11
  • Unspecified Infection1

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 30, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 22661806 ↗
  • InjuryJan 30, 2025Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 21271453 ↗
  • InjuryJan 9, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 21109026 ↗
  • InjuryJan 9, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 21108965 ↗
  • InjuryDec 12, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 20911160 ↗
  • InjuryDec 12, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 20910852 ↗
  • InjuryDec 12, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 20910848 ↗
  • InjuryDec 12, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 20910844 ↗
  • InjuryNov 28, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE..

    Patient problems: Inadequate Osseointegration

    MAUDE report 20804112 ↗
  • InjuryNov 21, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION, INSTABILITY OF THE IMPLANT.

    Patient problems: Inadequate Osseointegration

    MAUDE report 20743043 ↗
  • InjuryJul 25, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 19825357 ↗
  • InjuryJul 14, 2024Failure to Osseointegrate; Failure to Osseointegrate

    FAILURE TO OSSEOINTEGRATE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 19737361 ↗

Other Implant, Endosseous, Root-Form devices

All Implant, Endosseous, Root-Form devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page