Skip to content

MIS CF5C-10420Recalls & reported problems

MIS Implants Technologies Ltd. · Lance CLEAR pack Coni. Con. implant D4.20 L10mm, SP · Class 2 · Implant

Adverse event reports
10
Deaths reported
0
Injuries reported
10
Recalls naming it
0

Summary

The FDA's MAUDE database contains 10 adverse event reports that list this exact device (DI 07290113994621), received between Jul 22, 2025 and Feb 16, 2026 — classified as 10 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (10 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 1 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 5 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate10

Patient problems

  • Failure of Implant10

Recent adverse event reports

The 10 most recent of 10 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 16, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT FAILURE.

    Patient problems: Failure of Implant

    MAUDE report 24344809 ↗
  • InjuryFeb 16, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT FAILURE.

    Patient problems: Failure of Implant

    MAUDE report 24344787 ↗
  • InjuryFeb 16, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT FAILURE.

    Patient problems: Failure of Implant

    MAUDE report 24344763 ↗
  • InjuryFeb 16, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT FAILURE.

    Patient problems: Failure of Implant

    MAUDE report 24344731 ↗
  • InjuryFeb 16, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT FAILURE.

    Patient problems: Failure of Implant

    MAUDE report 24344683 ↗
  • InjuryNov 5, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 23483397 ↗
  • InjuryOct 23, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 23376260 ↗
  • InjurySep 3, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 22949153 ↗
  • InjuryJul 23, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 22578695 ↗
  • InjuryJul 22, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 22568659 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.