MIS C1-D11375Recalls & reported problems
MIS Implants Technologies Ltd. · C1 XD coni. con. implant D3.75 L11.50mm , SP · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
Quick summary
This MIS C1 dental implant is placed in the jawbone to hold a replacement tooth. Reports mostly describe implants that failed to fuse with the bone or were lost afterward. There are 900 reports, no deaths and 900 injuries. No recalls name this device. Reports fell from 535 in the prior 12 months to 304 in the latest 12 months.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 911
- Deaths reported
- 0
- Injuries reported
- 911
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 911 adverse event reports that list this exact device (DI 07290113996144), received between Aug 27, 2024 and Sep 29, 2026 — classified as 911 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (706 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate706
- Osseointegration Problem197
- Loss of Osseointegration8
- Fracture1
Patient problems
- Failure of Implant900
- No Clinical Signs, Symptoms or Conditions9
- Inadequate Osseointegration2
- Inflammation1
- Unspecified Infection1
Recent adverse event reports
The 25 most recent of 911 reports, in the reporter's own words as published by the FDA.
InjurySep 29, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss. No patient injury was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50927273 ↗InjurySep 28, 2026Loss of Osseointegration
Patient problems: Inadequate Osseointegration
MAUDE report 50922910 ↗InjurySep 17, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50809114 ↗InjurySep 17, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss. there was no osseointegration.
Patient problems: Inadequate Osseointegration
MAUDE report 50801199 ↗InjurySep 16, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss. There was no reported injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50787550 ↗InjurySep 16, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss. No patient injury was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50786552 ↗InjurySep 15, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss. There was no reported injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50778581 ↗InjurySep 15, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss. There was no reported injury.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50774934 ↗InjurySep 12, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50746356 ↗InjurySep 12, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50746355 ↗InjurySep 9, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss. No patient injury was reported.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50691491 ↗InjuryAug 13, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50234537 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50226337 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss due to a lack of osseointegration.
Patient problems: Failure of Implant
MAUDE report 50226219 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss due to a lack of osseointegration.
Patient problems: Failure of Implant
MAUDE report 50226043 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50225093 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant failure.
Patient problems: Failure of Implant
MAUDE report 50223309 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant failure.
Patient problems: Failure of Implant
MAUDE report 50223156 ↗InjuryAug 12, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50222107 ↗InjuryAug 11, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant failure.
Patient problems: Failure of Implant
MAUDE report 50203461 ↗InjuryAug 10, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50196321 ↗InjuryAug 7, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant failure.
Patient problems: Failure of Implant
MAUDE report 50173598 ↗InjuryJul 28, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50060222 ↗InjuryJul 28, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss; Fibrointegration.
Patient problems: Failure of Implant
MAUDE report 50060170 ↗InjuryJul 28, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Failure of Implant
MAUDE report 50060139 ↗
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page