Paltop 24-70007Recalls & reported problems
Paltop Advanced Dental Solutions Ltd · Dynamic Conical Dental Implant Ø4.2mm L10mm · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Paltop Dynamic Conical dental implant is a root-form screw placed into the jawbone. The 57 reports mostly describe the implant failing to fuse with the surrounding bone, with a smaller number describing bone loss after it had already fused; a few mention pain or infection. All 57 report injuries and no deaths, and no recalls name this device. Reports jumped from 3 in the prior 12 months to 54 in the most recent 12 months.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 56
- Deaths reported
- 0
- Injuries reported
- 56
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 56 adverse event reports that list this exact device (DI 07290114691314), received between Oct 17, 2025 and Sep 29, 2026 — classified as 56 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (54 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate54
- Loss of Osseointegration2
Patient problems
- No Clinical Signs, Symptoms or Conditions49
- Inadequate Osseointegration8
- Pain3
- Unspecified Infection2
Recent adverse event reports
The 25 most recent of 56 reports, in the reporter's own words as published by the FDA.
InjurySep 29, 2026Failure to Osseointegrate
Failed to osseointegrate.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50928226 ↗InjuryAug 3, 2026Failure to Osseointegrate
Failure of osseointegration.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50113372 ↗InjuryJul 6, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25714869 ↗InjuryJun 29, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25649826 ↗InjuryJun 24, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25606542 ↗InjuryJun 22, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25573129 ↗InjuryJun 16, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25515361 ↗InjuryJun 16, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25515232 ↗InjuryJun 15, 2026Failure to Osseointegrate
InjuryJun 15, 2026Failure to Osseointegrate
InjuryJun 14, 2026Failure to Osseointegrate
FAILURE OF OSSEOINTEGRATION
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25497584 ↗InjuryJun 10, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25458196 ↗InjuryJun 9, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25443742 ↗InjuryJun 8, 2026Failure to Osseointegrate
FAILURE OF OSSEOINTEGRATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25425456 ↗InjuryJun 8, 2026Failure to Osseointegrate
FAILURE OF OSSEOINTEGRATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25425448 ↗InjuryJun 8, 2026Failure to Osseointegrate
FAILURE OF OSSEOINTEGRATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25425426 ↗InjuryJun 8, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25423819 ↗InjuryJun 8, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25423816 ↗InjuryJun 8, 2026Failure to Osseointegrate
InjuryJun 7, 2026Failure to Osseointegrate
InjuryJun 7, 2026Failure to Osseointegrate
FAILURE OF OSSEOINTEGRATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25421055 ↗InjuryJun 7, 2026Failure to Osseointegrate
InjuryJun 4, 2026Failure to Osseointegrate
InjuryJun 4, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25387795 ↗InjuryJun 1, 2026Failure to Osseointegrate
FAILED TO OSSEOINTEGRATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25346762 ↗
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page