Skip to content

Brånemark System® 32117Recalls & reported problems

Nobel Biocare AB · Brånemark System® Mk III Groovy NP 3.3x15mm · Class 2 · Implant

All models of Brånemark System (141)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Nobel Biocare Brånemark dental implant is a screw-shaped root implant used as an anchor for replacement teeth. The 48 adverse event reports mostly describe the implant losing its bond with the surrounding jawbone, so the implant fails and has to be removed; a few also mention infection or pain. All48 reports involve injuries, with no deaths, and no recalls name this device. Reports fell from 16 in the previous 12 months to 4 in the latest 12 months.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
48
Deaths reported
0
Injuries reported
48
Recalls naming it
0

Summary

The FDA's MAUDE database contains 48 adverse event reports that list this exact device (DI 07332747000894), received between Nov 6, 2021 and Apr 18, 2026 — classified as 48 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (44 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 10 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 2 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 4 reportsFeb 2025: 0 reportsMar 2025: 6 reportsApr 2025: 2 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 2 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 2 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202610
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration44
  • Failure to Osseointegrate2
  • Osseointegration Problem2

Patient problems

  • Failure of Implant40
  • Unspecified Infection12
  • Pain2

Recent adverse event reports

The 25 most recent of 48 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 18, 2026Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 24920885 ↗
  • InjuryApr 18, 2026Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 24920884 ↗
  • InjuryDec 4, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 23722846 ↗
  • InjuryDec 4, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 23722809 ↗
  • InjuryAug 20, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 22856044 ↗
  • InjuryAug 20, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 22855943 ↗
  • InjuryJul 23, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 22583120 ↗
  • InjuryJul 23, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Unspecified Infection

    MAUDE report 22582743 ↗
  • InjuryApr 3, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21769241 ↗
  • InjuryApr 3, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21769235 ↗
  • InjuryMar 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21500740 ↗
  • InjuryMar 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21500738 ↗
  • InjuryMar 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21500731 ↗
  • InjuryMar 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21500728 ↗
  • InjuryMar 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21500709 ↗
  • InjuryMar 1, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21500705 ↗
  • InjuryJan 28, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21260580 ↗
  • InjuryJan 28, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21260572 ↗
  • InjuryJan 28, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21260540 ↗
  • InjuryJan 28, 2025Loss of Osseointegration; Loss of Osseointegration

    LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 21260538 ↗
  • InjuryOct 2, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 20354137 ↗
  • InjuryOct 2, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 20353971 ↗
  • InjuryJul 17, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 19765593 ↗
  • InjuryJul 17, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 19765590 ↗
  • InjuryJul 17, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 19765586 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →