Replace® Select 28947Recalls & reported problems
Nobel Biocare AB · Replace Select Straight TiU NP 3.5x11.5 · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
Quick summary
This Nobel Biocare Replace Select dental implant is a screw-shaped titanium post used to anchor a replacement tooth in the jawbone. The 46 reports mostly describe the implant failing to bond with the surrounding bone, or losing that bond after surgery, along with infection, pain, and numbness;46 injuries and no deaths were reported. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 48
- Deaths reported
- 0
- Injuries reported
- 48
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 48 adverse event reports that list this exact device (DI 07332747022506), received between Sep 11, 2019 and Sep 11, 2026 — classified as 48 injuries.
The most frequently reported specific device problem is “Loss of Osseointegration” (28 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Loss of Osseointegration28
- Failure to Osseointegrate18
- Osseointegration Problem2
Patient problems
- Failure of Implant40
- Unspecified Infection16
- Pain8
- Implant Pain2
- Numbness2
Recent adverse event reports
The 25 most recent of 48 reports, in the reporter's own words as published by the FDA.
InjurySep 11, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50743837 ↗InjurySep 11, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50743824 ↗InjuryMay 22, 2026Loss of Osseointegration
InjuryMay 22, 2026Loss of Osseointegration
InjuryMar 25, 2026Loss of Osseointegration
InjuryMar 25, 2026Loss of Osseointegration
InjuryMar 14, 2026Loss of Osseointegration
InjuryMar 14, 2026Loss of Osseointegration
InjuryMar 24, 2025Failure to Osseointegrate; Failure to Osseointegrate
InjuryMar 24, 2025Failure to Osseointegrate; Failure to Osseointegrate
InjuryAug 26, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 20071698 ↗InjuryAug 26, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 20069937 ↗InjuryJul 26, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 19844109 ↗InjuryJul 26, 2024Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 19843984 ↗InjuryJul 19, 2024Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant
MAUDE report 19783242 ↗InjuryJul 19, 2024Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant
MAUDE report 19783200 ↗InjuryNov 29, 2023Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant
MAUDE report 18232968 ↗InjuryNov 29, 2023Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant
MAUDE report 18232966 ↗InjuryOct 20, 2023Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant
MAUDE report 17979408 ↗InjuryOct 20, 2023Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant
MAUDE report 17979310 ↗InjurySep 5, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 17686635 ↗InjurySep 5, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 17685382 ↗InjurySep 5, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 17685380 ↗InjurySep 5, 2023Failure to Osseointegrate; Failure to Osseointegrate
IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.
Patient problems: Failure of Implant
MAUDE report 17685379 ↗InjuryJul 20, 2023Loss of Osseointegration; Loss of Osseointegration
IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.
Patient problems: Failure of Implant; Unspecified Infection
MAUDE report 17366507 ↗
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.