Skip to content

NobelZygoma™ 38280 (UDI 07332747102703)Recalls & reported problems

Nobel Biocare AB · NobelZygoma™ 0° 45mm · Class 2 · Implant

All models of NobelZygoma (36)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
12
Deaths reported
0
Injuries reported
12
Recalls naming it
0

Summary

The FDA's MAUDE database contains 12 adverse event reports that list this exact device (DI 07332747102703), received between Dec 2, 2019 and Jul 28, 2026 — classified as 12 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 4 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration6
  • Failure to Osseointegrate4
  • Osseointegration Problem2

Patient problems

  • Failure of Implant8
  • No Clinical Signs, Symptoms or Conditions4
  • Numbness2
  • Pain2

Recent adverse event reports

The 12 most recent of 12 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 28, 2026Loss of Osseointegration

    Loss of osseointegration.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50062102 ↗
  • InjuryJul 28, 2026Loss of Osseointegration

    Loss of osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50062100 ↗
  • InjuryJul 28, 2026Loss of Osseointegration

    Loss of osseointegration.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50062098 ↗
  • InjuryJul 28, 2026Loss of Osseointegration

    Loss of osseointegration.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50062093 ↗
  • InjuryDec 9, 2022Osseointegration Problem; Osseointegration Problem

    IMPLANT FAILED DUE TO OSSEOINTEGRATION PROBLEM.

    Patient problems: Failure of Implant

    MAUDE report 15954701 ↗
  • InjuryDec 9, 2022Osseointegration Problem; Osseointegration Problem

    IMPLANT FAILED DUE TO OSSEOINTEGRATION PROBLEM.

    Patient problems: Failure of Implant

    MAUDE report 15953575 ↗
  • InjuryApr 27, 2022Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 14224968 ↗
  • InjuryApr 27, 2022Loss of Osseointegration; Loss of Osseointegration

    IMPLANT FAILED DUE TO A LOSS OF OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 14224953 ↗
  • InjuryNov 17, 2021Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Numbness; Pain

    MAUDE report 12831407 ↗
  • InjuryNov 17, 2021Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED DUE TO A FAILURE TO OSSEOINTEGRATE.

    Patient problems: Failure of Implant; Numbness; Pain

    MAUDE report 12831399 ↗
  • InjuryJan 21, 2020Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED BECAUSE PRIMARY STABILITY COULD NOT BE ACHIEVED.

    Patient problems: Failure of Implant

    MAUDE report 9609928 ↗
  • InjuryDec 2, 2019Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED DUE TO INCORRECT IMPLANT SIZE SELECTION.

    Patient problems: Failure of Implant

    MAUDE report 9394513 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page