NobelSpeedy® 32150 (UDI 07332747159844)Recalls & reported problems
Nobel Biocare AB · NobelSpeedy® Groovy RP 4.0x13mm · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
Quick summary
This Nobel Biocare NobelSpeedy dental implant is a screw placed in the jawbone to hold a replacement tooth. Most reports describe implants that failed to bond with the jawbone, and some mention infection, pain or numbness. The records include 1,983 reports and 1,968 injuries, with no deaths, and no recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 2,038
- Deaths reported
- 0
- Injuries reported
- 2,023
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2,038 adverse event reports that list this exact device (DI 07332747159844), received between Nov 1, 2021 and Sep 30, 2026 — classified as 2,023 injuries, 15 malfunctions.
The most frequently reported specific device problem is “Failure to Osseointegrate” (1,053 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate1,053
- Loss of Osseointegration787
- Osseointegration Problem76
- Patient Device Interaction Problem48
- Fracture26
- Adverse Event Without Identified Device or Use Problem22
- Material Deformation10
- Migration10
Patient problems
- Failure of Implant1,258
- No Clinical Signs, Symptoms or Conditions392
- Unspecified Infection299
- Pain169
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available137
- Numbness56
- Abscess36
- Fistula24
Recent adverse event reports
The 25 most recent of 2,038 reports, in the reporter's own words as published by the FDA.
InjurySep 30, 2026Failure to Osseointegrate
Patient problems: Unspecified Infection
MAUDE report 50954163 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: Unspecified Infection
MAUDE report 50954162 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: Unspecified Infection
MAUDE report 50954005 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: Unspecified Infection
MAUDE report 50954004 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50953686 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50953683 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: Unspecified Infection
MAUDE report 50953612 ↗InjurySep 30, 2026Failure to Osseointegrate
Patient problems: Unspecified Infection
MAUDE report 50953608 ↗InjurySep 29, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50939986 ↗InjurySep 29, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50939985 ↗InjurySep 17, 2026Osseointegration Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50811346 ↗InjurySep 17, 2026Osseointegration Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50811345 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Aspiration/Inhalation
MAUDE report 50795960 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Aspiration/Inhalation
MAUDE report 50795959 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Aspiration/Inhalation
MAUDE report 50795929 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Aspiration/Inhalation
MAUDE report 50795926 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50795742 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50795738 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50795721 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50795720 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50795659 ↗InjurySep 16, 2026Loss of Osseointegration
Patient problems: Unspecified Infection
MAUDE report 50795657 ↗InjurySep 15, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50780930 ↗InjurySep 15, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50780926 ↗InjurySep 14, 2026Loss of Osseointegration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50764796 ↗
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page