Navina™ Classic System Small 69007 (REF 6900740)Recalls & reported problems

Wellspect AB · Navina Classic Transanal Irrigation. 1 Navina Classic control unit, 1 Water container, 1 Tube set, 2 Rectal catheters small, 1 Accessory set, 1 Navina case. Non Sterile Device. Rx Only. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07333387026589), received between May 21, 2026 and May 21, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Free or Unrestricted Flow” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Free or Unrestricted Flow1

Patient problems

  • Vomiting1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 21, 2026Free or Unrestricted Flow

    A COMPLAINT WAS RECEIVED INVOLVING A NAVINA CLASSIC IRRIGATION SYSTEM CONTROL UNIT. THE USER REPORTED THAT UPON REPLACING THE PUMP AND TUBING SET, IRRIGATION FLUID FLOWED THROUGH THE SYSTEM WITHOUT MANUAL PUMPING WHEN THE WATER CONTROL SWITCH WAS IN THE "ON" POSITION. THE REPORTED FLOW RATE WAS SIGNIFICANTLY HIGHER THAN EXPECTED, WITH APPROXIMATELY 300 ML OF IRRIGATION FLUID INFUSED IN LESS THAN ONE MINUTE, COMPARED TO THE TYPICAL INFUSION TIME OF 2-3 MINUTES. DURING USE OF THE AFFECTED CONTROL UNIT, THE PATIENT (PEDIATRIC USER WITH SPINA BIFIDA) EXPERIENCED EPISODES OF VOMITING DURING IRRIGATION, INCLUDING ONE INSTANCE OF EMESIS ON ONE DAY AND TWO INSTANCES ON ANOTHER DAY. NO MEDICAL TREATMENT WAS SOUGHT, AND NO HOSPITALIZATION OR SERIOUS INJURY WAS REPORTED. THE USER DISCONTINUED USE OF THE NEW CONTROL UNIT AFTER THREE DAYS AND RESUMED USE OF A PREVIOUS CONTROL UNIT WITH THE SAME TUBING, AFTER WHICH THE ISSUE WAS NOT OBSERVED.

    Patient problems: Vomiting

    MAUDE report 25239447 ↗

Other Tubes, gastrointestinal (and accessories) devices

All Tubes, gastrointestinal (and accessories) devices →