CERAMENT™BONE VOID FILLER A0210-08Recalls & reported problems
Bone Support AB · CERAMENT BONE VOID FILLER is a fast-setting, injectable and moldable ceramic bone graft substitute intended for filling bone voids/gaps. The material consists of a powder and a liquid component. The major constituents of the powder are hydroxyapatite and calcium sulfate hemihydrate. The liquid component (C-TRU) contains Iohexol as a radio-contrast enhancer. Mixing the components with the combined mixing injection (CMI) device, results in a viscous material intended to set ex vivo or in vivo. By combining hydroxyapatite and calcium sulfate a balance is achieved between implant resorption rate and bone in-growth rate. Calcium sulfate acts as a resorbable carrier for hydroxyapatite. Hydroxyapatite has a slow resorption rate, high osteoconductivity, promoting bone in-growth and gives long term structural support to newly formed bone. The ceramic bone graft substitute is placed into the bone defect under visual inspection or under radiographic monitoring during open or percutaneous surgery. The paste may be injected into the defect, molded by hand and digitally placed into the defect, or used to prepare beads that are placed into the defect. The accompanying injection device (ID) and Tip Extenders may be used to facilitate the filling of the bone defect. When fully set in vivo, CERAMENT BONE VOID FILLER is drillable and can be used to augment hardware during the surgical procedure. · Class 2 · Implant
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07350055430035), received between Jan 13, 2020 and Apr 26, 2024 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Device Dislodged or Dislocated2
- Migration2
- Off-Label Use1
- Tear, Rip or Hole in Device Packaging1
Patient problems
- Infiltration into Tissue2
- Inflammation2
- Post Operative Wound Infection2
- Wound Dehiscence2
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryApr 26, 2024Off-Label Use; Device Dislodged or Dislocated; Migration; Off-Label Use; Device Dislodged or Dislocated; Migration
POST-OPERATIVELY THE INCISION HEALED NICELY THEN WEEKS LATER THE INCISION OPENED AND STARTED DRAINING LIQUID CERAMENT. ON SECOND OPERATION, ALL OF THE CERAMENT WITHIN THE CAVITY WAS LIQUID - NOT SOLID. RETURN TO OPERATING ROOM TO REMOVE CERAMENT AND RE-CLOSE THE INCISION. UNNECESSARY ANESTHESIA, COST OF RE-OPERATION. ENTEROBACTER CLOACAE COMPLEX INFECTION DUE TO OPEN WOUND REQUIRING INFECTIOUS DISEASE CONSULT, IV FOLLOWED BY LONG TERM PO ANTIBIOTICS. SIGNIFICANT DELAY IN PATIENT'S ABILITY TO RETURN TO ACTIVITY.
Patient problems: Infiltration into Tissue; Inflammation; Post Operative Wound Infection; Wound Dehiscence
MAUDE report 19189458 ↗InjuryApr 26, 2024Device Dislodged or Dislocated; Migration; Device Dislodged or Dislocated; Migration
POST-OPERATIVELY THE INCISION HEALED NICELY THEN WEEKS LATER THE INCISION OPENED AND STARTED DRAINING LIQUID CERAMENT. ON SECOND OPERATION, ALL OF THE CERAMENT WITHIN THE CAVITY WAS LIQUID - NOT SOLID. RETURN TO OPERATING ROOM TO REMOVE CERAMENT AND RE-CLOSE THE INCISION. UNNECESSARY ANESTHESIA, COST OF RE-OPERATION. INFECTION (MRSA) DUE TO OPEN WOUND REQUIRING LONG TERM ANTIBIOTICS. SIGNIFICANT DELAY IN PATIENT'S ABILITY TO RETURN TO ACTIVITY.
Patient problems: Infiltration into Tissue; Inflammation; Post Operative Wound Infection; Wound Dehiscence
MAUDE report 19189437 ↗MalfunctionJan 13, 2020Tear, Rip or Hole in Device Packaging
ACCORDING TO CUSTOMER THERE WAS A HOLE IN THE PACKAGE (TYVEK POUCH) WHICH WAS THE STERILE BARRIER. THE HOLE WAS DISCOVERED BEFORE USE OF THE DEVICE AND THE DEVICE WAS NEVER IMPLANTED. THE DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION BUT WITHOUT THE TYVEK POUCH. THE INVESTIGATION WAS CLOSED BECAUSE LACK OF INFORMATION. NO OTHER COMPLAINTS HAVE BEEN REPORTED TO THE MANUFACTURER CONCERNING HOLE IN THE PACKAGE (TYVEK POUCH).
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 9580376 ↗
FDA clearance and classification
The FDA regulates product code MQV (filler, bone void, calcium compound) under 21 CFR 888.3045 as a Class II device. 21 CFR 888.3045 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CERAMENT™BONE VOID FILLER A0210-08
Has the CERAMENT™BONE VOID FILLER A0210-08 been recalled?
No FDA recall record in our data names this exact device identifier (DI 07350055430035), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CERAMENT™BONE VOID FILLER A0210-08?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Jan 13, 2020 and Apr 26, 2024. In those reports, the most common specific device problems are “Device Dislodged or Dislocated” (2), “Migration” (2) and “Off-Label Use” (1); the most common patient problems are “Infiltration into Tissue” (2), “Inflammation” (2) and “Post Operative Wound Infection” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CERAMENT™BONE VOID FILLER A0210-08?
None of the reports are classified as deaths, 2 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CERAMENT™BONE VOID FILLER A0210-08 MRI safe?
According to the device's FDA GUDID record, its labeling does not contain MRI safety information. Ask the manufacturer or the radiology team before an MRI.
Who makes the CERAMENT™BONE VOID FILLER A0210-08, and is it still sold?
The FDA's device database lists Bone Support AB as the company responsible for it (brand CERAMENT™BONE VOID FILLER, model A0210-08). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Filler, Bone Void, Calcium Compound devices
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44150Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND3 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42275Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls1 report
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T44145Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42200Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T42280Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND2 recalls0 reports
- MAGNIFUSE® Bone Graft 7509014Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND1 recall2 reports
- GRAFTON®and GRAFTON PLUS®Demineralized Bone Matrix (DBM) T43102Medtronic Sofamor Danek, Inc. · FILLER, BONE VOID, CALCIUM COMPOUND1 recall2 reports
- HydroSet XT 897005Stryker Corporation · FILLER, BONE VOID, CALCIUM COMPOUND1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page