OSSDSIGN Cranial PSI XLRecalls & reported problems

Ossdsign AB · OSSDSIGN Cranial PSI (Patient Specific Implant) is a device that replaces native bone in the cranial skeleton. Each Cranial PSI is a patient-specific device specifically created for a patient’s unique anatomical requirements. Cranial PSI consists of a rigid titanium mesh that is largely covered by biocompatible ceramic tiles. The ceramic tiles are in a mosaic pattern that provides space between tiles to allow free circulation of fluids (510(k) no. K161090) · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07350086550115), received between Dec 19, 2018 and Dec 19, 2018 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fracture” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Fracture1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 19, 2018Fracture; Fracture

    IT WAS REPORTED THAT THE PATIENT SPECIFIC IMPLANT ARRIVED AT THE OR WITH A FIXATION ARM BROKEN OFF. THE FIXATION ARM WAS CONTAINED WITHIN ITS PROTECTIVE SILICON SLEEVE AND THE DOUBLE STERILE PACKAGING REMAINED INTACT. SURGEON DECIDED TO USE THE IMPLANT AND PROCEEDED TO TRIM AWAY THE PIECE OF THE REMAINING FIXATION ARM. DURING THE TRIMMING A SMALL FRACTURE WAS INTRODUCED ON AN ADJACENT CERAMIC TILE DUE TO THE APPLIED FORCE. THE FIT OF THE IMPLANT WAS DEEMED AS GOOD AND THE REMAINING 5 FIXATION ARMS WERE USED TO FIXATE THE IMPLANT TO THE CRANIUM. OTHERWISE THE SURGERY WAS UNEVENTFUL AND NO COMPLICATIONS HAVE BEEN REPORTED SO FAR IN REGARD TO PATIENT OUTCOME.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8179301 ↗

FDA clearance and classification

The FDA regulates product code GXN (plate, cranioplasty, preformed, non-alterable) under 21 CFR 882.5330 as a Class II device. 21 CFR 882.5330 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the OSSDSIGN Cranial PSI XL

Has the OSSDSIGN Cranial PSI XL been recalled?

No FDA recall record in our data names this exact device identifier (DI 07350086550115), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the OSSDSIGN Cranial PSI XL?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Dec 19, 2018. That report lists device problem “Fracture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the OSSDSIGN Cranial PSI XL?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the OSSDSIGN Cranial PSI XL MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the OSSDSIGN Cranial PSI XL, and is it still sold?

The FDA's device database lists Ossdsign AB as the company responsible for it (brand OSSDSIGN Cranial PSI, model XL). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Plate, Cranioplasty, Preformed, Non-Alterable devices

All Plate, Cranioplasty, Preformed, Non-Alterable devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page