Skip to content

ASTRA TECH Implant System® 24942Recalls & reported problems

Dentsply Implants Manufacturing GmbH · OsseoSpeed® TX 4.0 S - 11 mm · Class 2 · Implant

All models of ASTRA TECH Implant System (166)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Dentsply Astra Tech OsseoSpeed dental implant is placed in the jawbone. Its 2,408 reports are all injury reports, mostly describing the implant coming loose or not bonding with the bone, and mention inflammation, infection and bone loss around the implant. Some mention fractures. There are no deaths, and no recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
2,440
Deaths reported
0
Injuries reported
2,440
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2,440 adverse event reports that list this exact device (DI 07392532108310), received between Jun 16, 2023 and Sep 30, 2026 — classified as 2,440 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (1,203 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 82 reportsDec 2023: 42 reportsJan 2024: 75 reportsFeb 2024: 74 reportsMar 2024: 69 reportsApr 2024: 81 reportsMay 2024: 51 reportsJun 2024: 105 reportsJul 2024: 65 reportsAug 2024: 68 reportsSep 2024: 73 reportsOct 2024: 71 reportsNov 2024: 63 reportsDec 2024: 21 reportsJan 2025: 68 reportsFeb 2025: 35 reportsMar 2025: 121 reportsApr 2025: 17 reportsMay 2025: 27 reportsJun 2025: 55 reportsJul 2025: 92 reportsAug 2025: 63 reportsSep 2025: 53 reportsOct 2025: 43 reportsNov 2025: 63 reportsDec 2025: 52 reportsJan 2026: 69 reportsFeb 2026: 47 reportsMar 2026: 50 reportsApr 2026: 58 reportsMay 2026: 62 reportsJun 2026: 52 reportsJul 2026: 91 reportsAug 2026: 29 reportsSep 2026: 31 reportsOct 2026: 0 reports202420252026121
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration1,203
  • Failure to Osseointegrate1,165
  • Fracture58
  • Damaged Thread11
  • Insufficient Device Problem Information4
  • Malposition of Device3
  • Crack2
  • Overfill1

Patient problems

  • Failure of Implant2,407
  • Inflammation557
  • Unspecified Infection525
  • Osteolysis230
  • Pocket Erosion159
  • No Clinical Signs, Symptoms or Conditions22
  • Inadequate Osseointegration13
  • Implant Pain7

Recent adverse event reports

The 25 most recent of 2,440 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50950527 ↗
  • InjurySep 30, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50948579 ↗
  • InjurySep 30, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss with progressive bone loss and periimplantitis.

    Patient problems: Inadequate Osseointegration; Inflammation; Osteolysis

    MAUDE report 50947628 ↗
  • InjurySep 29, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50936376 ↗
  • InjurySep 29, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. Concomitant product: Standard abutment Astra.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50932860 ↗
  • InjurySep 29, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50932457 ↗
  • InjurySep 29, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss. No patient injury was reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50927280 ↗
  • InjurySep 28, 2026Loss of Osseointegration

    Patient problems: Inadequate Osseointegration; Inflammation; Osteolysis

    MAUDE report 50924255 ↗
  • InjurySep 20, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50834769 ↗
  • InjurySep 19, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50832709 ↗
  • InjurySep 19, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50832512 ↗
  • InjurySep 19, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50832511 ↗
  • InjurySep 19, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50832496 ↗
  • InjurySep 18, 2026Fracture

    Patient problems: Inadequate Osseointegration

    MAUDE report 50828251 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50817340 ↗
  • InjurySep 18, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50813452 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50813424 ↗
  • InjurySep 17, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50809807 ↗
  • InjurySep 17, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50808684 ↗
  • InjurySep 17, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50806456 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50805913 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss. No patient injury was reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50805084 ↗
  • InjurySep 17, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant failure.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50805014 ↗
  • InjurySep 16, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50791338 ↗
  • InjurySep 15, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50776648 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates