Skip to content

ASTRA TECH Implant System® EV 25246Recalls & reported problems

Dentsply Implants Manufacturing GmbH · OsseoSpeed® EV 4.8 S - 15 mm · Class 2 · Implant

All models of ASTRA TECH Implant System EV (177)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
15
Deaths reported
0
Injuries reported
15
Recalls naming it
0

Summary

The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 07392532132773), received between Sep 13, 2023 and Jan 9, 2026 — classified as 15 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (10 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 2 reportsOct 2025: 0 reportsNov 2025: 5 reportsDec 2025: 0 reportsJan 2026: 2 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate10
  • Loss of Osseointegration5

Patient problems

  • Failure of Implant15
  • Unspecified Infection5
  • Inflammation3
  • Implant Pain1
  • Osteomyelitis1

Recent adverse event reports

The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 9, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 24016821 ↗
  • InjuryJan 4, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 23954199 ↗
  • InjuryNov 21, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED AN UNSPECIFIED INFECTION AND A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 23613954 ↗
  • InjuryNov 19, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 23601213 ↗
  • InjuryNov 19, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 23601208 ↗
  • InjuryNov 12, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 23536366 ↗
  • InjuryNov 11, 2025Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation; Osteomyelitis

    MAUDE report 23526602 ↗
  • InjurySep 12, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 23045589 ↗
  • InjurySep 12, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 23045587 ↗
  • InjuryAug 12, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 19960293 ↗
  • InjuryApr 4, 2024Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 19041333 ↗
  • InjuryJan 22, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 18553433 ↗
  • InjuryJan 19, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 18544782 ↗
  • InjuryNov 22, 2023Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 18194140 ↗
  • InjurySep 13, 2023Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Implant Pain; Inflammation

    MAUDE report 17737406 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page