Skip to content

ASTRA TECH Implant System® EV 25253Recalls & reported problems

Dentsply Implants Manufacturing GmbH · OsseoSpeed® EV 5.4 S - 9 mm · Class 2 · Implant

All models of ASTRA TECH Implant System EV (177)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Quick summary

This Astra Tech Implant System is a dental implant that is placed into the jawbone. Most of the 210 reports describe implants that did not bond with the bone or later became loose, and some mention fractures, infection or bone loss around the implant. The reports include 210 injuries and no deaths. No recalls name this device. Reports dropped to 47 in the last 12 months, from 75 in the 12 months before.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
215
Deaths reported
0
Injuries reported
215
Recalls naming it
0

Summary

The FDA's MAUDE database contains 215 adverse event reports that list this exact device (DI 07392532132889), received between Jun 18, 2023 and Sep 30, 2026 — classified as 215 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (104 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 6 reportsDec 2023: 1 reportsJan 2024: 6 reportsFeb 2024: 10 reportsMar 2024: 5 reportsApr 2024: 6 reportsMay 2024: 5 reportsJun 2024: 6 reportsJul 2024: 5 reportsAug 2024: 10 reportsSep 2024: 6 reportsOct 2024: 3 reportsNov 2024: 5 reportsDec 2024: 1 reportsJan 2025: 6 reportsFeb 2025: 6 reportsMar 2025: 10 reportsApr 2025: 1 reportsMay 2025: 1 reportsJun 2025: 8 reportsJul 2025: 5 reportsAug 2025: 14 reportsSep 2025: 13 reportsOct 2025: 5 reportsNov 2025: 4 reportsDec 2025: 4 reportsJan 2026: 7 reportsFeb 2026: 7 reportsMar 2026: 3 reportsApr 2026: 6 reportsMay 2026: 4 reportsJun 2026: 6 reportsJul 2026: 5 reportsAug 2026: 1 reportsSep 2026: 5 reportsOct 2026: 0 reports20242025202614
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration104
  • Failure to Osseointegrate93
  • Fracture19
  • Malposition of Device2
  • Crack1
  • Insufficient Device Problem Information1
  • Migration or Expulsion of Device1
  • Off-Label Use1

Patient problems

  • Failure of Implant209
  • Unspecified Infection65
  • Inflammation44
  • Pocket Erosion21
  • Osteolysis17
  • No Clinical Signs, Symptoms or Conditions3
  • Insufficient Information2
  • Abscess1

Recent adverse event reports

The 25 most recent of 215 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Fracture

    Patient problems: Unspecified Infection

    MAUDE report 50941567 ↗
  • InjurySep 18, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50815566 ↗
  • InjurySep 9, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50697005 ↗
  • InjurySep 8, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50670161 ↗
  • InjurySep 3, 2026Fracture

    It was reported that a patient experienced a dental implant fracture associated with peri-implantitis. The dental implant was explanted as a result.

    Patient problems: Insufficient Information

    MAUDE report 50591643 ↗
  • InjuryAug 25, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50435407 ↗
  • InjuryJul 27, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss; mobility.

    Patient problems: Failure of Implant

    MAUDE report 50013905 ↗
  • InjuryJul 27, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss/MOBILITY/1 IMPLANT INVOLVED.

    Patient problems: Failure of Implant

    MAUDE report 50005839 ↗
  • InjuryJul 17, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS, INFECTION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 25852446 ↗
  • InjuryJul 16, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS; MOBILITY.

    Patient problems: Failure of Implant

    MAUDE report 25847341 ↗
  • InjuryJul 9, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 25773869 ↗
  • InjuryJun 30, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS, INFECTION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 25672032 ↗
  • InjuryJun 24, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS/LOOSENING - INFECTION, PERIIMPLANTITIS.

    Patient problems: Failure of Implant; Inflammation; Unspecified Infection

    MAUDE report 25613009 ↗
  • InjuryJun 19, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 25562555 ↗
  • InjuryJun 8, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. THE PATIENT ALSO REPORTED TO HAVE HAD INFLAMMATION.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 25428664 ↗
  • InjuryJun 5, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 25407516 ↗
  • InjuryJun 3, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS, INFECTION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 25374841 ↗
  • InjuryMay 27, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. AND ALSO REPORTED WAS OSTEOLYSIS.

    Patient problems: Failure of Implant; Osteolysis

    MAUDE report 25299149 ↗
  • InjuryMay 12, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS; 2 IMPLANTS INVOLVED.

    Patient problems: Failure of Implant

    MAUDE report 25155703 ↗
  • InjuryMay 5, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS ASSOCIATED WITH PROGRESSIVE BONE LOSS.

    Patient problems: Failure of Implant; Osteolysis

    MAUDE report 25086019 ↗
  • InjuryMay 5, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. ALSO, IT WAS REPORTED THAT THEY HAD INFLAMMATION.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 25084182 ↗
  • InjuryApr 30, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS - MOBILITY, OSTEOLYSIS.

    Patient problems: Failure of Implant; Osteolysis

    MAUDE report 25049918 ↗
  • InjuryApr 23, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS DUE TO PROGRESSIVE BONE LOSS.

    Patient problems: Failure of Implant; Osteolysis

    MAUDE report 24964983 ↗
  • InjuryApr 20, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Osteolysis

    MAUDE report 24925342 ↗
  • InjuryApr 18, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED AN IMPLANT MOBILITY ISSUE, PERIIMPLANTITIS AND A SUBSEQUENT DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 24919514 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page