Skip to content

XiVE® 32262440 (REF 26-2440)Recalls & reported problems

Dentsply Implants Manufacturing GmbH · XiVE® S plus Implant D3.8/L8 · Class 2 · Implant

All models of XiVE (62)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This Dentsply XiVE S Plus dental implant is placed in the jawbone to hold a replacement tooth. Reports mostly describe implants that failed to fuse with the bone or were lost afterward, and some mention infection, inflammation or bone loss. There are 899 reports, no deaths and 899 injuries. No recalls name this device. Reports fell from 277 in the prior 12 months to 129 in the latest 12 months.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
906
Deaths reported
0
Injuries reported
906
Recalls naming it
0

Summary

The FDA's MAUDE database contains 906 adverse event reports that list this exact device (DI 07392532208843), received between Jun 19, 2023 and Sep 28, 2026 — classified as 906 injuries.

The most frequently reported specific device problem is “Failure to Osseointegrate” (460 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 23 reportsDec 2023: 34 reportsJan 2024: 33 reportsFeb 2024: 26 reportsMar 2024: 19 reportsApr 2024: 36 reportsMay 2024: 25 reportsJun 2024: 31 reportsJul 2024: 25 reportsAug 2024: 36 reportsSep 2024: 30 reportsOct 2024: 47 reportsNov 2024: 42 reportsDec 2024: 4 reportsJan 2025: 18 reportsFeb 2025: 22 reportsMar 2025: 48 reportsApr 2025: 2 reportsMay 2025: 26 reportsJun 2025: 11 reportsJul 2025: 37 reportsAug 2025: 26 reportsSep 2025: 29 reportsOct 2025: 12 reportsNov 2025: 15 reportsDec 2025: 12 reportsJan 2026: 23 reportsFeb 2026: 13 reportsMar 2026: 8 reportsApr 2026: 17 reportsMay 2026: 9 reportsJun 2026: 13 reportsJul 2026: 10 reportsAug 2026: 5 reportsSep 2026: 11 reportsOct 2026: 0 reports20242025202648
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Osseointegrate460
  • Loss of Osseointegration407
  • Fracture40
  • Malposition of Device1
  • Material Deformation1

Patient problems

  • Failure of Implant895
  • Unspecified Infection233
  • Inflammation147
  • Osteolysis78
  • Pocket Erosion57
  • Inadequate Osseointegration6
  • No Clinical Signs, Symptoms or Conditions5
  • Tooth Loss3

Recent adverse event reports

The 25 most recent of 906 reports, in the reporter's own words as published by the FDA.

  • InjurySep 28, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50926470 ↗
  • InjurySep 28, 2026Fracture

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50924419 ↗
  • InjurySep 17, 2026Loss of Osseointegration

    Patient problems: Inadequate Osseointegration

    MAUDE report 50812452 ↗
  • InjurySep 15, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50778342 ↗
  • InjurySep 15, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50770286 ↗
  • InjurySep 11, 2026Loss of Osseointegration

    Patient problems: Inadequate Osseointegration

    MAUDE report 50740030 ↗
  • InjurySep 11, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50733537 ↗
  • InjurySep 10, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. There was no reported injury.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50715511 ↗
  • InjurySep 9, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Inadequate Osseointegration

    MAUDE report 50689210 ↗
  • InjurySep 7, 2026Failure to Osseointegrate

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50654961 ↗
  • InjurySep 7, 2026Loss of Osseointegration

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50654035 ↗
  • InjuryAug 25, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss.

    Patient problems: Failure of Implant

    MAUDE report 50438160 ↗
  • InjuryAug 13, 2026Loss of Osseointegration

    Patient problems: Failure of Implant

    MAUDE report 50234860 ↗
  • InjuryAug 12, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss due to infection.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 50223756 ↗
  • InjuryAug 7, 2026Failure to Osseointegrate

    It was reported that a patient experienced a dental implant loss. Also, it was reported that they had unspecified infection.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 50170046 ↗
  • InjuryAug 4, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. Also, it was reported that they had unspecified infection and inflammation.

    Patient problems: Failure of Implant; Inflammation; Unspecified Infection

    MAUDE report 50127065 ↗
  • InjuryJul 30, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. The patient also reported to have had inflammation.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 50081749 ↗
  • InjuryJul 27, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. The patient also reported to have had inflammation.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 50028510 ↗
  • InjuryJul 27, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss. The patient also reported to have had inflammation.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 50009756 ↗
  • InjuryJul 17, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. AND ALSO REPORTED WAS OSTEOLYSIS

    Patient problems: Failure of Implant; Osteolysis

    MAUDE report 25853673 ↗
  • InjuryJul 15, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. ALSO, IT WAS REPORTED THAT THEY HAD INFLAMMATION.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 25824855 ↗
  • InjuryJul 14, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 25811478 ↗
  • InjuryJul 9, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS / LOOSENING BECAUSE OF BONE RESORPTION.

    Patient problems: Failure of Implant

    MAUDE report 25769092 ↗
  • InjuryJul 2, 2026Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 25691610 ↗
  • InjuryJul 1, 2026Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 25682981 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates