Skip to content

XiVE® 32252433Recalls & reported problems

Dentsply Implants Manufacturing GmbH · XiVE® TG plus Implant D3.4/L13 · Class 2 · Implant

All models of XiVE (62)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
14
Deaths reported
0
Injuries reported
14
Recalls naming it
0

Summary

The FDA's MAUDE database contains 14 adverse event reports that list this exact device (DI 07392532212147), received between Oct 17, 2023 and Aug 11, 2026 — classified as 14 injuries.

The most frequently reported specific device problem is “Loss of Osseointegration” (9 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 2 reportsMay 2024: 2 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 2 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 4 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Loss of Osseointegration9
  • Failure to Osseointegrate4
  • Fracture1

Patient problems

  • Failure of Implant14
  • Pocket Erosion6
  • Inflammation5
  • Unspecified Infection4

Recent adverse event reports

The 14 most recent of 14 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 11, 2026Loss of Osseointegration

    It was reported that a patient experienced a dental implant loss due to Periimplantitis.

    Patient problems: Failure of Implant; Inflammation

    MAUDE report 50212971 ↗
  • InjuryJul 30, 2025Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation; Pocket Erosion

    MAUDE report 22672414 ↗
  • InjuryJul 30, 2025Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation; Pocket Erosion

    MAUDE report 22672412 ↗
  • InjuryJul 30, 2025Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation; Pocket Erosion

    MAUDE report 22672410 ↗
  • InjuryJul 30, 2025Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Inflammation; Pocket Erosion

    MAUDE report 22672408 ↗
  • InjuryMar 26, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21699966 ↗
  • InjuryMar 26, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS AND MOBILITY ISSUES.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 21698864 ↗
  • InjuryMay 7, 2024Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Pocket Erosion

    MAUDE report 19258939 ↗
  • InjuryMay 7, 2024Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Pocket Erosion

    MAUDE report 19258826 ↗
  • InjuryApr 18, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 19135316 ↗
  • InjuryApr 18, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 19135251 ↗
  • InjuryFeb 22, 2024Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 18757901 ↗
  • InjuryNov 21, 2023Fracture; Fracture

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 18181348 ↗
  • InjuryOct 17, 2023Loss of Osseointegration; Loss of Osseointegration

    IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.

    Patient problems: Failure of Implant

    MAUDE report 17948592 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page