Astra Tech Implant System® EV 26304Recalls & reported problems
Dentsply Implants Manufacturing GmbH · Astra Tech Implant EV 3.0 S - 13 mm OsseoSpeed® · Class 2 · Implant
All models of ASTRA TECH Implant System EV (177)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Dentsply Astra Tech Implant EV is a screw-shaped device placed into bone. All 182 reports are injuries and there are no deaths. Most describe the implant failing to bond with the bone or being lost, and some mention infection or bone loss around it. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 185
- Deaths reported
- 0
- Injuries reported
- 185
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 185 adverse event reports that list this exact device (DI 07392532214158), received between Jun 27, 2023 and Sep 29, 2026 — classified as 185 injuries.
The most frequently reported specific device problem is “Failure to Osseointegrate” (165 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Failure to Osseointegrate165
- Loss of Osseointegration17
- Off-Label Use15
- Insufficient Device Problem Information6
- Crack1
- Fracture1
Patient problems
- Failure of Implant182
- Unspecified Infection48
- Inflammation15
- Osteolysis13
- Pocket Erosion10
- Insufficient Information6
- Inadequate Osseointegration3
- Implant Pain2
Recent adverse event reports
The 25 most recent of 185 reports, in the reporter's own words as published by the FDA.
InjurySep 29, 2026Failure to Osseointegrate
It was reported that a patient experienced a dental implant loss.
Patient problems: Inadequate Osseointegration
MAUDE report 50930227 ↗InjurySep 18, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss with periimplantitis.
Patient problems: Inadequate Osseointegration; Inflammation
MAUDE report 50816420 ↗InjurySep 18, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss with periimplantitis.
Patient problems: Inadequate Osseointegration; Inflammation
MAUDE report 50816261 ↗InjuryJul 27, 2026Loss of Osseointegration
It was reported that a patient experienced a dental implant loss. Also, it was reported that they had inflammation.
Patient problems: Failure of Implant; Inflammation
MAUDE report 50028537 ↗InjuryJul 15, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 25829804 ↗InjuryJul 1, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 25680279 ↗InjuryJun 26, 2026Loss of Osseointegration
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 25634184 ↗InjuryJun 8, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS, INFECTION, OSTEOLYSIS.
Patient problems: Failure of Implant; Osteolysis; Unspecified Infection
MAUDE report 25437653 ↗InjuryMay 25, 2026Loss of Osseointegration
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 25272525 ↗InjuryApr 24, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. THIS FAILED DUE TO AN INFECTION.
Patient problems: Failure of Implant
MAUDE report 24979430 ↗InjuryApr 22, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS, PERIIMPLANTITIS.
Patient problems: Failure of Implant; Inflammation
MAUDE report 24958026 ↗InjuryApr 20, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant; Unspecified Infection
MAUDE report 24931225 ↗InjuryApr 20, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 24931199 ↗InjuryApr 16, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 24904197 ↗InjuryApr 13, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. AN UNSPECIFIED INFECTION WAS ALSO REPORTED.
Patient problems: Failure of Implant; Unspecified Infection
MAUDE report 24867707 ↗InjuryMar 31, 2026Failure to Osseointegrate
CUSTOMER REPORTED IMPLANT LOSS, (B)(6). PERIIMPLANTITIS.
Patient problems: Failure of Implant; Inflammation
MAUDE report 24744474 ↗InjuryMar 24, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED AN UNSPECIFIED INFECTION, PERIIMPLANTITIS AND A SUBSEQUENT DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant; Inflammation; Unspecified Infection
MAUDE report 24671700 ↗InjuryMar 23, 2026Loss of Osseointegration
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant; Osteolysis
MAUDE report 24670422 ↗InjuryMar 16, 2026Failure to Osseointegrate
CUSTOMER REPORTED IMPLANT LOSS.
Patient problems: Failure of Implant; Unspecified Infection
MAUDE report 24605935 ↗InjuryMar 3, 2026Off-Label Use; Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS. THE IMPLANT WAS PLACED IN A CONTRAINDICATED POSITION.
Patient problems: Failure of Implant
MAUDE report 24495513 ↗InjuryMar 2, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant; Unspecified Infection
MAUDE report 24481946 ↗InjuryMar 2, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant
MAUDE report 24481927 ↗InjuryFeb 10, 2026Failure to Osseointegrate
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant; Unspecified Infection
MAUDE report 24309993 ↗InjuryFeb 9, 2026Failure to Osseointegrate
CUSTOMER REPORTED IMPLANT LOSS. IMPLANT CAME OUT WHEN REMOVING COVER SCREW.
Patient problems: Failure of Implant
MAUDE report 24291770 ↗InjuryFeb 9, 2026Failure to Osseointegrate; Insufficient Device Problem Information
IT WAS REPORTED THAT A PATIENT EXPERIENCED A DENTAL IMPLANT LOSS.
Patient problems: Failure of Implant; Insufficient Information
MAUDE report 24290560 ↗
Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM43,616 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM40,404 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM27,400 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,621 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLA Titanium BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM25,298 reports
- Straumann® Dental Implant System Roxolid® SLA Impl. SLA Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM23,448 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,320 reports
- STRAUMANN BONE LEVEL TAPERED IMPLANT SLActive Roxolid BLInstitut Straumann AG · IMPLANT, ENDOSSEOUS, ROOT-FORM22,267 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.