Seraclone® Anti-c (RH4) 802346100Recalls & reported problems

Bio-Rad Medical Diagnostics GmbH · Blood Grouping Reagent Anti-c (RH4); Seraclone® Human Monoclonal (MS33); for tube test; 5ml

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07611969950461), received between Apr 2, 2024 and Apr 2, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “False Positive Result” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • False Positive Result1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 2, 2024False Positive Result; False Positive Result

    THE CUSTOMER REPORTED A FALSE POSITIVE REACTION WITH SERACLONE ANTI-C (RH4). THE CUSTOMER RETURNED A PRODUCT SAMPLE FOR INVESTIGATIONAL TESTING. THE RETURNED SAMPLE WAS VISUALLY INSPECTED IN COMPARISON TO THE RETENTION SAMPLES STORED IN OUR QUALITY CONTROL LABORATORY WITH THE LABEL NUMBERS #00002, #00324 AND THE RETENTION SAMPLE WITH THE LABEL NUMBER #00238. A SLIGHT CLOUDINESS AND A MORE INTENSE YELLOWISH COLOR WERE NOTICEABLE IN THE SAMPLE RETURNED BY THE CUSTOMER. ADDITIONALLY, THE COMPLAINT SAMPLE WAS TESTED FOR SPECIFICITY WITH VARIOUS RED BLOOD CELLS AND THE CUSTOMER´S FINDING WAS CONFIRMED. THE COMPLAINT SAMPLE SHOWED UNEXPECTED POSITIVE RESULTS WITH C (RH4) ANTIGEN NEGATIVE RED BLOOD CELLS. FOR FURTHER TESTS, THE RED BLOOD CELLS USED WERE SELECTED IN ORDER TO BE ABLE TO IDENTIFY THE SPECIFICITY OF THE CONTAMINATION OF THE CUSTOMER VIAL. CONTAMINATION WITH SERACLONE ANTI-D AND SERACLONE ANTI-E WAS CLEARLY RULED OUT. BASED ON THE TEST RESULTS THAT ALL C POSITIVE CELLS SHOWED A POSITIVE RESULT, A CONTAMINATION WITH SERACLONE ANTI-C WAS VERY LIKELY. THE RETENTION SAMPLE WAS TESTED FOR SPECIFICITY AND POTENCY AND MET ALL ACCEPTANCE CRITERIA. THE UNEXPECTED FALSE POSITIVE REACTIO

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19019628 ↗