Biotestcell® A1 & B 816057100Recalls & reported problems

Bio-Rad Medical Diagnostics GmbH · Reagent Red Blood Cells; Biotestcell® A1 & B; 3.0 - 3.4%; pooled cells for reverse grouping by the tube test; 2x10ml

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07611969952663), received between Apr 16, 2020 and May 21, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “False Positive Result” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • False Positive Result2

Patient problems

  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 21, 2024False Positive Result; False Positive Result

    THE CUSTOMER REPORTED UNEXPECTED POSITIVE REACTIONS OF PATIENT SAMPLES WITH BIOTESTCELL A1&B IN THE REVERSE TYPING. THE CUSTOMER STATED THAT SHE A PATIENT SAMPLE WITH AN ANTI-M CAUSED INTERFERENCES WITH BIOTESTCELL A1&B. FURTHERMORE, THE CUSTOMER STATED THAT THE REVERSE TYPING REAGENT RED BLOOD CELLS OF ORTHO WOULD BE M ANTIGEN NEGATIVE. THE DUSTOMER DID NOT PROVIDE A DATE OF EVENT. THE CUSTOMER DID NEITHER RETURN A PRODUCT SAMPLE OF BIOTESTCELL A1&B, LOT 9402011-00 FOR INVESTIGATIONAL TESTING NOR THE PATIENT SAMPLE THAT SHOWED INTERFERENCES. THEREFORE, OUR QUALITY CONTROL LABORATORY TESTED THEIR RETENTION SAMPLES OF THE CURRENT LOTS OF BIOTESTCELL A1&B: LOT 9402011-00 (LOT THE CUSTOMER FILED HER COMPLAINT FOR), LOT 9406011-00 AND LOT 9410011-00 WITH DIFFERENT DONOR SAMPLES ACCORDING TO THE INSTRUCTION FOR USE (IFU). ALL ACCEPTANCE CRITERIA WERE MET. WE DID NOT OBSERVE ANY FALSE POSITIVE REACTION. WITHIN THE PRODUCTION PROCESS BIOTESTCELL A1&B WAS TESTED FOR THE ABO BLOODGROUPS, THE RH PHENOTYPES AND THE ANTIGENS KELL (KEL1) AND CELLANO (KEL2) ACCORDING TO THE REQUIREMENTS. THE ACCEPTANCE CRITERIA WERE MET. TESTING FOR FURTHER ANTIGENS WAS NOT MANDATORY. BASED ON THE INVESTIGATION

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19357772 ↗
  • MalfunctionApr 16, 2020False Positive Result

    THE CUSTOMER REPORTED ISSUES WITH BIOTESTCELL A1&B. THE CUSTOMER STATED THAT THERE ARE PATIENTS THAT GENERATED WHAT SHE DESCRIBED AS ROULEAUX FORMATION IN THE REVERSE TYPING. THE CUSTOMER STATED THAT SHE SAW THE EXTRA REACTION (FALSE POSITIVE) REACTION WITH BIOTESTCELL A1. FURTHERMORE SHE REPORTED THAT THEY USED SUCCESSFULLY A SALINE REPLACEMENT ACCORDING TO THE AABB TECHNICAL MANUAL TO RESOLVE UNEXPECTED POSITIVE REACTIONS. THE EXACT DATE OF EVENT IS NOT KNOWN. THE CUSTOMER HAS NOT RETURNED THE SUPPOSEDLY DEFECTIVE PRODUCT BIOTESTCELL A1&B FOR INVESTIGATIONAL TESTING BUT WILL PROVIDE TWO PATIENT SAMPLES THAT HAD CAUSED FALSE POSITIVE TEST RESULTS. IN THE MEAN TIME OUR QUALITY CONTROL LABORATORY TESTED THEIR RETENTION SAMPLE WITH DIFFERENT DONOR SAMPLES IN THE TUBE TECHNIQUE. ALL POSITIVE AND NEGATIVE REACTIONS WERE CORRECT. WE DID NOT OBSERVE ANY FALSE POSITIVE REACTION RESPECTIVELY ROULEAUX FORMATION. ADDITIONALLY THE BLOOD GROUP A RESPECTIVELY B OF THE RETENTION SAMPLE WAS CONFIRMED WITH THE BLOOD GROUPING REAGENTS SERACLONE ANTI-A, SERACLONE ANTI-B, SERACLONE ANTI-AB, SERACLONE ANTI-A1 AND SERACLONE ANTI-H. AGAIN, ALL POSITIVE AND NEGATIVE REACTIONS WERE CORRECT. A REVIEW OF TH

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9966960 ↗