Scorpio 72-13-0908Recalls & reported problems
Howmedica Osteonics Corp. · Posterior Stabilized Tibial Insert · Class 2 · Implant
All models of Scorpio (107)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613153992592), received between Jul 11, 2018 and Jul 11, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Degraded” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Degraded1
Patient problems
- Injury1
- Osteolysis1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 11, 2018Degraded; Degraded
IT WAS REPORTED BY THE PATIENT TO THE LEGAL DEPARTMENT VIA TELEPHONE THAT FOLLOWING HIS RIGHT KNEE SURGERY HE BEGAN EXPERIENCING CLICKING, FELT MOVEMENT AND FELT LIKE HIS RIGHT KNEE WAS LOOSE. HE WAS REVISED ON (B)(6) 2012. UPDATE PER MEDICAL REVIEW: ¿ON (B)(6) 2012 REVISION OF THE RIGHT TOTAL KNEE, FEMUR, AND POLY EXCHANGE WAS PERFORMED FOR A POST-OPERATIVE DIAGNOSIS OF ASEPTIC LOOSENING WITH OSTEOLYSIS OF THE FEMORAL COMPONENT. THE OPERATIVE REPORT DESCRIBES SPINAL ANESTHESIA AND A TOURNIQUET TIME OF FIFTY-FIVE MINUTES. THE OPERATIVE REPORT NOTES, "SYNOVIUM HAD THE LOOK OF OSTEOLYSIS". THE FEMORAL COMPONENT WAS GROSSLY LOOSE AND EASILY REMOVED. THE POLY SHOWED EVIDENCE OF CEMENT ABRASION AND WEAR OF POLY POST. THE FEMORAL CEMENT WAS REMOVED AND THE CANAL WAS PREPARED FOR REVISION COMPONENTS.¿
Patient problems: Injury; Osteolysis
MAUDE report 7680527 ↗
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page