Restoration 6276-7-122Recalls & reported problems
Howmedica Osteonics Corp. · Modular Hip System · Class 2 · Implant
All models of Restoration (86)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613154058686), received between Apr 25, 2022 and Apr 25, 2022 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Bone Fracture(s)1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 25, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DURING CUP IMPACTION OF A RECENT THA CASE, WE RESULTED IN HAVING ACETABULAR FRACTURES. SURGICAL DELAY > 30 MINUTES. CASE TYPE / APPLICATION: THA. UPDATE 01/APRIL/2022: PER MPS: PLEASE PROVIDE DETAILS AS TO ALL MEASURES TAKEN TO ADDRESS THE ACETABULAR FRACTURES: PLATING THE POSTERIOR ACETABULUM WALL. FURTHER FRACTURES WERE NOT DISCOVERED UNTIL LATER ON. IT WAS REPORTED THE SHELL WAS PART OF THE FRACTURE EVENT IMPLANTED BUT REMOVED THE FOLLOWING DAY FOR A REVISION CUP. UPDATE: IT HAS BEEN REPORTED THAT IMPLANT MALPOSITION DID NOT CAUSE OR CONTRIBUTE TO THIS EVENT. IT HAS BEEN REPORTED TOO MUCH FORCE OR OVERSIZED CUP LEAD TO THIS. (PERIPROSTHETIC FRACTURE ONLY) IT HAS BEEN REPORTED THAT NO BONE PIN HOLES HAVE CAUSED OR CONTRIBUTED TO THIS EVENT. UPDATE 14/APRIL/2022: PER MPS: INTRA-OPERATIVELY ON (B)(6) 2022, A DISTAL FEMORAL FRACTURE HAD ALSO BEEN NOTICED VIA C-ARM. ON (B)(6) 2022, THE PATIENT WAS REVISED TO COMPETITOR ACETABULAR COMPONENTS, RESTORATION MODULAR PROXIMAL BODY, FEMORAL HEAD, AND THREE CABLE AND SLEEVE SETS.
Patient problems: Bone Fracture(s)
MAUDE report 14192094 ↗
Other Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented devices
- BIOLOX DELTA 1365-32-310Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented551 reports
- PINNACLE ALTRX 1221-36-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented481 reports
- BIOLOX DELTA 1365-32-320Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death314 reports
- BIOLOX DELTA 1365-36-720Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented1 death189 reports
- DJO SURGICAL 400-03-362Encore Medical, L.P. · Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented187 reports
- Anthology 71365705Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented176 reports
- BIOLOX DELTA 1365-40-710Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented170 reports
- PINNACLE GRIPTION 1217-32-054Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/ceramic/polymer, cemented or non-porous, uncemented169 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page