Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 07613252152118), received between Nov 22, 2016 and Apr 29, 2022 — classified as 1 injury, 7 malfunctions.
The most frequently reported specific device problem is “Fracture” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fracture5
- Break3
- Material Deformation3
- Mechanical Problem2
- Detachment of Device or Device Component1
- Material Protrusion/Extrusion1
Patient problems
- No Known Impact Or Consequence To Patient6
- No Consequences Or Impact To Patient2
- Failure of Implant1
- Injury1
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 29, 2022Fracture; Fracture
IT WAS REPORTED THAT THE LOCKING MECHANISM OF AN AVIATOR ONE LEVEL PLATE DETACHED POST-OPERATIVELY CAUSING AN AVIATOR SCREW TO MIGRATE. THE DEVICES REMAIN IMPLANTED, REVISION SURGERY HAS NOT BEEN SCHEDULED OR PERFORMED AT THIS TIME. THIS REPORT CAPTURES THE PLATE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14255468 ↗MalfunctionMar 5, 2019Break; Fracture; Fracture
IT WAS REPORTED THAT LOCKING RING ON PLATE BROKE OFF. ALL BROKEN FRAGMENTS WERE RETRIEVED. A SURGICAL DELAY OF A MINUTE OR TWO WAS REPORTED. THE PLATE WAS LEFT IN THE PATIENT. NO ADVERSE CONSEQUENCES TO THE PATIENT WAS REPORTED AT THIS TIME. THIS WILL BE REPORTED DUE TO THE POSSIBILITY OF SCREW PULL OUT IN THE FUTURE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 8392080 ↗MalfunctionSep 18, 2018Detachment of Device or Device Component; Material Deformation; Material Deformation
SPRING BAR POPPED OFF PLATE WHEN ADVANCING SCREW ON ADJACENT SIDE OF THE PLATE. THE 10 MINUTE DELAY TO REPLACE PLATE AND SCREWS. NO ADVERSE CONSEQUENCES WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7884623 ↗MalfunctionJun 6, 2018Fracture; Mechanical Problem; Fracture
IT IS REPORTED THAT UPON ATTEMPTING TO INSERT SCREW INTO THE PLATE THE LOCKING MECHANISM FAILED AND NO LONGER WOULD LOCK. SURGEON JUST USED ANOTHER PLATE OF THE SAME SIZE. NO ADVERSE CONSEQUENCES AND NO SURGICAL DELAY REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7572707 ↗InjuryJan 10, 2018Break; Fracture; Fracture
IT WAS REPORTED THAT; AVIATOR PLATE WAS REMOVED DUE TO BROKEN LOCKING MECHANISM.
Patient problems: Failure of Implant; Injury
MAUDE report 7180284 ↗MalfunctionJul 17, 2017Fracture; Break; Fracture
IT WAS REPORTED THAT TH LOCKING MECHANISM BROKE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 6720065 ↗MalfunctionApr 18, 2017Mechanical Problem; Material Deformation; Material Protrusion/Extrusion; Material Deformation
IT WAS REPORTED THAT 14MM PLATE LOCKING MECHANISM FELL OFF THE TRACK ON LOCKING AND WAS PROTRUDING.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6501563 ↗MalfunctionNov 22, 2016Material Deformation
IT WAS REPORTED THAT THEY WERE DOING AN ACDF WITH PLATING AND THAT WHEN PLACING THE SCREWS INTO THE PLATE, THE SILVER LOCKING WING ON THE PLATE APPEARED TO DEFORM. THE SURGEON DID NOT WANT TO CONTINUE USING THIS PARTICULAR PLATE, SO SWAPPED IT FOR A NEW ONE OF THE SAME SIZE AND MAKE. UPDATE: THE SURGEON FURTHER REPORTED THAT HE PUT THE SCREW IN AND THEN WANTED TO REPOSITION IT. WHEN HE TRIED TO REMOVE THE SCREW, IT HAD GONE PAST THE LOCKING MECHANISM AND BROKE AS IT WAS TAKEN OUT. HE SAID HE BROKE THE WING ON THE PLATE. THE SCREW DID NOT BREAK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6120193 ↗
Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- Elegance® Anterior Cervical Plate 53430353Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430108Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430114Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430240Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- Elegance® Anterior Cervical Plate 53430236Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page