ORTHOMAP 6007-616-000Recalls & reported problems

Stryker Leibinger GmbH & Co. KG · VERSATILE HIP 2.0 SOFTWARE · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
11
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 11 adverse event reports that list this exact device (DI 07613327004250), received between Feb 22, 2019 and Nov 7, 2025 — classified as 11 malfunctions.

The most frequently reported specific device problem is “Image Display Error/Artifact” (10 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Image Display Error/Artifact10
  • Imprecision8
  • Incorrect Measurement1

Patient problems

  • No Consequences Or Impact To Patient10
  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 11 most recent of 11 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 7, 2025Incorrect Measurement; Incorrect Measurement

    NO NEW INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23500570 ↗
  • MalfunctionSep 26, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED BY THE USER FACILITY THAT DURING A PROCEDURE, THERE WAS AN INACCURACY BY THE DEVICE, AND AT ONE POINT THE INACCURACY WAS 15MM. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9124799 ↗
  • MalfunctionSep 26, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    THE USER FACILITY REPORTED THE DEVICE WAS INACCURATE DURING A CASE; THE DOCTOR REAMED TO 3MM SHORT OF THE MOST MEDIAL ASPECT AND RECORDED IT AS THE NEW ZERO. DURING CUP INSERTION, IT WAS REPORTED THAT THERE WAS 10MM DISTANCE TO REACH THE NEW ZERO. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 9123963 ↗
  • MalfunctionSep 3, 2019Image Display Error/Artifact; Image Display Error/Artifact

    IT WAS REPORTED THAT THE DEVICE HAD DEPTH TO SEAT ACCURACY ISSUES. THERE WERE NO REPORTED ADVERSE CONSEQUENCES; THERE WERE NO SIGNIFICANT PROCEDURE DELAYS; THERE WAS NO MEDICAL INTERVENTION REQUIRED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8956760 ↗
  • MalfunctionAug 19, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED THAT DURING A PROCEDURE AT THE USER FACILITY THE DEPTH TO SEAT WAS SHOWING AN INACCURATE VALUE, DURING TOTAL HIP WHILE USING VERSATILE HIP SOFTWARE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8905778 ↗
  • MalfunctionJul 12, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED THAT THE SURGEON'S DEPTH TO SEAT NUMBERS WERE INCREASING WHEN THY IMPACTED THE CUP DEEPER AS OPPOSED TO DECREASING. THERE WERE NO REPORTED ADVERSE CONSEQUENCES; THERE WERE NO PROCEDURE DELAYS; THERE WAS NO MEDICAL INTERVENTION REQUIRED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8785903 ↗
  • MalfunctionJul 12, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED THAT THE SURGEON'S DEPTH TO SEAT NUMBERS WERE INCREASING WHEN THY IMPACTED THE CUP DEEPER AS OPPOSED TO DECREASING. THERE WERE NO REPORTED ADVERSE CONSEQUENCES; THERE WERE NO PROCEDURE DELAYS; THERE WAS NO MEDICAL INTERVENTION REQUIRED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8785902 ↗
  • MalfunctionJun 26, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED BY THE USER FACILITY THAT DURING A PROCEDURE, THERE WAS AN INACCURACY BY THE DEVICE, AND AT ONE POINT THE INACCURACY WAS 15MM. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8736500 ↗
  • MalfunctionApr 29, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED THAT DURING A PROCEDURE AT THE USER FACILITY THE DEPTH OF THE HIP SOFTWARE WAS OFF. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8560138 ↗
  • MalfunctionApr 29, 2019Image Display Error/Artifact; Imprecision; Image Display Error/Artifact; Imprecision

    IT WAS REPORTED THAT DURING A PROCEDURE AT THE USER FACILITY THE DEPTH OF THE HIP SOFTWARE WAS OFF. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8560136 ↗
  • MalfunctionFeb 22, 2019Image Display Error/Artifact; Image Display Error/Artifact

    IT WAS REPORTED BY THE USER FACILITY THAT DURING A LEG LENGTH VERIFICATION POST PROCEDURE, THERE WAS AN INACCURACY BY THE DEVICE. THE DEVICE REFLECTED A LENGTH THAT WAS LONGER THAN THE ACTUAL LENGTH. THE EXACT INACCURACY WAS UNKNOWN, BUT LESS THAN 11MM. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY; NO ADVERSE CONSEQUENCES OR MEDICAL INTERVENTION WERE REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8362670 ↗

Other Neurological stereotaxic Instrument devices

All Neurological stereotaxic Instrument devices →