V40 Head 6260-5-428Recalls & reported problems
Howmedica Osteonics Corp. · V40 Femoral Head · Class 2 · Implant
All models of V40 Head (30)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327012958), received between Oct 23, 2020 and Oct 23, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Degraded” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Degraded1
- Loss of Osseointegration1
Patient problems
- Hip Fracture1
- Inadequate Osseointegration1
- Metal Related Pathology1
- Osteolysis1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryOct 23, 2020Degraded; Loss of Osseointegration; Degraded; Loss of Osseointegration
THIS PI IS FOR REVISION1. I HAD THA REVISION SURGERY ON (B)(6) 2018. THE STEM WAS REPLACED WITH A STRYKER RESTORATION MODULAR ONE. THE 28 MM CERAMIC FEMORAL HEAD WAS REPLACED WITH A COCR HEAD. HIP, GROIN, AND THIGH PAIN CONTINUED. ON (B)(6) 2019, I WAS DIAGNOSED WITH A STRESS FRACTURE AT THE TIP OF THE PROSTHETIC STEM. ON (B)(6) 2020, I HAD A BONE GRAFT TO REPAIR THE FRACTURE. A CLOUDY MILKY YELLOW FLUID ALONG WITH METAL DEBRIS WAS DISCOVERED IN THE HIP JOINT. ALSO, THERE WAS OSTEOLYSIS IN THE PROXIMAL FEMORAL FEMUR. THE ACETABULAR HAD OVERHANGING SCAR TISSUE AND BONE. THE TRUNION HAD STRIPE WEAR INDICATING IMPINGEMENT AND LIKELY SOURCE OF THE METALLOSIS. THE 28 MM FEMORAL HEAD WAS REPLACED WITH A 40MM COCR HEAD. SYMPTOMS OF METALLOSIS CONTINUE. FDA SAFETY REPORT ID# (B)(4). UPDATE: AS PER THE PATIENT, HE HAD A LEFT THA ON (B)(6) 2016. HE STARTED TO EXPERIENCE PAIN AT THE END OF (B)(6) 2016. THE PATIENT HAD A BONE SCAN DONE ON (B)(6) 2017 (APPROX.) WHICH INDICATED INFECTION/IMPLANT LOOSENING. NO TREATMENT WAS GIVEN TO THE PATIENT. ON (B)(6) 2017 (APPROX.) HE WAS PLACED ON ORAL ANTIBIOTICS FOR 30 DAYS DUE TO INFECTION. ON (B)(6) 2017 X-RAYS CONFIRMED LOOSENING AND THE PATIENT WAS RE
Patient problems: Hip Fracture; Inadequate Osseointegration; Metal Related Pathology; Osteolysis; Pain
MAUDE report 10731083 ↗
Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous devices
- Accolade 6021-0537Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous46 reports
- PROFEMUR® PHAC1252Microport Orthopedics Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous37 reports
- Accolade 6020-0335Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous35 reports
- OXINIUM 71342340Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous32 reports
- EXETER 0580-1-351Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous29 reports
- INSTRUMENT 2101-0200Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous27 reports
- REFLECTION 71330001Smith & Nephew, Inc. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous20 reports
- Accolade 6720-0330Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, porous18 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.