Secur-Fit 6054-0711SRecalls & reported problems
Howmedica Osteonics Corp. · 127 Degree Neck Angle Hip Stem · Class 2 · Implant
All models of Secur-Fit (45)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 07613327020847), received between Aug 27, 2018 and Aug 27, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K041170, K051738); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration1
Patient problems
- Bone Fracture(s)1
- Injury1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryAug 27, 2018Migration; Migration
IT WAS REPORTED THAT PATIENT'S RIGHT HIP WAS REVISED AFTER PATIENT COMPLAINT OF LIMB LENGTH DISCREPANCY AND PAIN. X-RAY REVEALED THAT STEM HAD SUBSIDED. IT WAS DISCOVERED THAT SUBSIDENCE OCCURRED PROGRESSIVELY AFTER PATIENT SUFFERED AN UNREPORTED PERIPROSTHETIC FRACTURE THAT THE PATIENT DECIDED TO LET GO UNTREATED. PATIENT HAD A REPORTED BMI OF 39. THE LINER AND HEAD WERE EXCHANGED FOR LARGER-SIZED STRYKER DEVICES. THE STEM AND SHELL REMAINED IN THE PATIENT.
Patient problems: Bone Fracture(s); Injury; Pain
MAUDE report 7818689 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K041170, K051738. One submission often covers many models, so check the product and lot details in each record.
- Z-0894-2009 · Nov 13, 2008 · TerminatedPrimary Secur-fit Plus Max Hip Stem These devices are modular components of a total hip system. These femoral stems are intended for use with femoral heads and acetabular componen
- Z-0893-2009 · Nov 13, 2008 · TerminatedSecur-Fit Max Hip Stem These devices are modular components of a total hip system. These femoral stems are intended for use with femoral heads and acetabular components in primary
Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices
- Novation 130-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls156 reports
- Novation 130-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls79 reports
- CORAIL 3L92511Depuy (Ireland) · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate158 reports
- Acumatch A Series 138-36-29Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate3 recalls1 report
- Novation 136-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls43 reports
- Novation 130-32-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls33 reports
- Novation 132-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls26 reports
- Novation 136-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls22 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page