Omnifit 6097-0835Recalls & reported problems
Howmedica Osteonics Corp. · 127 Degree Cemented Hip Stem · Class 2 · Implant
All models of Omnifit (43)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327022391), received between Feb 7, 2019 and Nov 26, 2019 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Osseointegration Problem” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K983226); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Osseointegration Problem1
- Packaging Problem1
Patient problems
- Inadequate Osseointegration1
- Injury1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryNov 26, 2019Osseointegration Problem; Osseointegration Problem
AS REPORTED: "RIGHT REVISION THA. DIAGNOSIS: FAILED RIGHT TOTAL HIP. NO FURTHER INFORMATION AVAILABLE PER HOSPITAL." REP HAS PROVIDED AN X-RAY AND EXPLANT PICTURES. UPDATE 31/OCTOBER/2019: SPOKE TO REP. PATIENT WAS REVISED DUE TO STEM LOOSENING. THE STEM, HEAD, LINER, AND DALL-MILES CABLE WERE REVISED. REP CONFIRMED THERE WERE NO ALLEGATIONS AGAINST THE HEAD AND LINER. NO ALLEGATIONS AGAINST THE DALL- MILES CABLE WERE REPORTED TO THE REP. AFTER IMPLANTING A CONSTRAINED LINER, THE SURGEON DECIDED HE WANTED TO GO WITH A NON- CONSTRAINED LINER INSTEAD (NO ALLEGATIONS AGAINST THE CONSTRAINED LINER). WHEN TRYING TO EXPLANT THE CONSTRAINED LINER, THE SHELL BECAME DISLODGED INTRA-OPERATIVELY AND WAS REVISED (NO PRIOR ALLEGATIONS TO THE SHELL OR PLAN TO REVISE IT). PATIENT'S BONE QUALITY IS UNKNOWN. PATIENT WAS REVISED TO A CEMENTED EXETER STEM, TRIDENT II SHELL, POLY LINER AND 36 -5 METAL HEAD.
Patient problems: Inadequate Osseointegration; Injury
MAUDE report 9378383 ↗MalfunctionFeb 7, 2019Packaging Problem; Packaging Problem
PRIMARY PROCEDURE, LEFT HIP. IT WAS REPORTED THAT AFTER REMOVING THE OUTER STERILE BLISTER FROM THE PRISTINE OUTER BOX, THE TYVEK COVERING WAS OBSERVED TO HAVE HOLES. THE OUTER BLISTER WAS OPENED AND HOLES WERE ALSO OBSERVED ON THE TYVEK OF THE INNER STERILE BLISTER. DUE TO STERILITY CONCERNS, THE DEVICE WAS NOT USED. SURGEON DECIDED TO IMPLANT A SIZE 7 STEM INSTEAD OF THE ORIGINAL SIZE 8 AS THE DEVICE WAS READILY AVAILABLE IN THE O.R. REP REPORTED THAT THERE WAS NO SURGICAL DELAY. THE DEVICE AND STERILE BLISTERS ARE AVAILABLE FOR RETURN, BUT THE HOSPITAL DISPOSED OF THE OUTER BOX. THE IMPLANT WAS NOT LISTED ON THE IMPLANT SHEET AS A WASTED/ IN AND OUT DEVICE. REP WAS PRESENT FOR THE PROCEDURE AND WITNESSED THE EVENT. REP REPORTED THAT X-RAYS, MEDICAL RECORDS, AND ADDITIONAL INFORMATION WILL NOT BE RELEASED BY THE HOSPITAL OR SURGEON.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8319107 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K983226. One submission often covers many models, so check the product and lot details in each record.
- Z-0899-2009 · Nov 13, 2008 · TerminatedOmnifit Eon These devices are modular components of a total hip system. These femoral stems are intended for use with femoral heads and acetabular components in primary or revisio
- Z-0898-2009 · Nov 13, 2008 · TerminatedOmnifit FC Cemented Stem These devices are modular components of a total hip system. These femoral stems are intended for use with femoral heads and acetabular components in prima
Other Prosthesis, hip, semi-constrained, metal/polymer, cemented devices
- NA 1365-51-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented753 reports
- NA 1365-50-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented412 reports
- ARTICUL/EZE 1365-21-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 recall280 reports
- ARTICUL/EZE 1365-11-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 death262 reports
- LFIT 6260-9-236Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, cemented256 reports
- PINNACLE GRIPTION 1217-32-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented2 deaths239 reports
- ELEOS™ 25002111EOnkos Surgical, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented3 deaths230 reports
- Novation 130-36-52Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented2 recalls124 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page