Scorpio 77-4005Recalls & reported problems
Howmedica Osteonics Corp. · Total Stabilizer Tibial Tray · Class 2 · Implant
All models of Scorpio (107)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 07613327029284), received between Mar 2, 2018 and Apr 5, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).
8 other recalls cover devices cleared under the same FDA submission (K994128); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device Operates Differently Than Expected1
- Failure to Disconnect1
- Material Distortion1
Patient problems
- No Consequences Or Impact To Patient1
- No Patient Involvement1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 5, 2018Failure to Disconnect; Failure to Disconnect
IN ORDER TO USE STEM EXTENSION, KEEL END-CAP FOR THE SCORPIO TS TIBIAL IMPLANT NEEDED TO BE REMOVED BUT FAILED. ANOTHER BACK-UP IMPLANT WAS AVAILABLE. THE BACK-UP IMPLANT WAS OPENED AND USED IN THE SURGERY. SURGICAL DELAY TIME WAS APPR. 5-10 MIN.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7400808 ↗MalfunctionMar 2, 2018Device Operates Differently Than Expected; Material Distortion; Device Operates Differently Than Expected; Material Distortion
THE SURGEON COULDN'T UNSCREW THE LOCKING SCREW ON THE SCORPIO TS TIBIAL TRAY FOR USING STEM EXTENSION, DURING THE SURGERY. SO, THE SURGEON CHANGED TO ANOTHER SCORPIO TS TIBIAL TRAY W/ DIFFERENT LOT NUMBER FOR SURGERY CLOSING. THERE WAS 5 ~ 10 MIN. DELAY OF SURGERY, DUE TO THE PROBLEM. LEFT KNEE.
Patient problems: No Patient Involvement
MAUDE report 7309198 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K994128. One submission often covers many models, so check the product and lot details in each record.
- Z-0877-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT-Intended for knee replacement Part Number:72-4-7512
- Z-0879-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT -Intended for knee replacment Part Number: 72-4-7516
- Z-0882-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-7524
- Z-0876-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-0510
- Z-0881-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-7521
- Z-0880-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT. Intended for knee replacement Part Number: 72-4-7518
- Z-0875-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-0321
- Z-0878-2024 · Dec 1, 2023 · Open, ClassifiedSCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-7514
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page