Skip to content

Kinematic 6485-2-108Recalls & reported problems

Howmedica Osteonics Corp. · Rotating Hinge Knee · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 07613327047479), received between Aug 5, 2025 and Aug 5, 2025 — classified as 3 injuries.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (1 report).

4 other recalls cover devices cleared under the same FDA submission (K001548, K223069, K972863); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 3 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Insufficient Device Problem Information1
  • Loss of Osseointegration1

Patient problems

  • Bone Fracture(s)1
  • Inadequate Osseointegration1
  • Swelling/ Edema1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryAug 5, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    INFORMATION RECEIVED FROM (B)(4) INDICATES THE FOLLOWING: PERIPROSTHETIC TIBIAL FRACTURE. TIBIAL COMPONENTS REVISED. RIGHT KNEE.

    Patient problems: Bone Fracture(s)

    MAUDE report 22719996 ↗
  • InjuryAug 5, 2025Insufficient Device Problem Information; Insufficient Device Problem Information

    INFORMATION RECEIVED FROM IIS 2023-001 INDICATES THE FOLLOWING: OTHER MECHANICAL FAILURE (PSEUDOCAPSULE AND RECURRENT EFFUSION). ALL COMPONENTS REMOVED. RIGHT KNEE.

    Patient problems: Swelling/ Edema

    MAUDE report 22717829 ↗
  • InjuryAug 5, 2025Loss of Osseointegration; Loss of Osseointegration

    INFORMATION RECEIVED FROM IIS 2023-001 INDICATES THE FOLLOWING: ASEPTIC LOOSENING. ALL COMPONENTS REMOVED. LEFT KNEE.

    Patient problems: Inadequate Osseointegration

    MAUDE report 22713680 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K001548, K223069, K972863. One submission often covers many models, so check the product and lot details in each record.

  • Z-0920-2024 · Dec 1, 2023 · Open, Classified
    DUR PCA MTK REV INS LFT Intended for knee replacement Product Number: 6728-2-611
  • Z-0919-2024 · Dec 1, 2023 · Open, Classified
    DUR PCA MTK REV INS LFT Intended for knee replacement Product Number: 6728-2-609
  • Z-0922-2024 · Dec 1, 2023 · Open, Classified
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-711
  • Z-0921-2024 · Dec 1, 2023 · Open, Classified
    DUR PCA MTK REV INS RT Intended for knee replacement Product Number: 6728-2-709

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page